EDI Integrator 2016 C++ Builder Edition
EDI Integrator 2016 C++ Builder Edition
Questions / Feedback?

Disconnected Event

Fired when a connection is closed.

Syntax

typedef void __fastcall (__closure *TibeMLLPClientDisconnectedEvent)(System::TObject* Sender, TibeMLLPClientDisconnectedEventParams *e);


__property TibeMLLPClientDisconnectedEvent OnDisconnected = {read=FOnDisconnected, write=FOnDisconnected};

typedef struct {
     int StatusCode;
     String Description;
} TibeMLLPClientDisconnectedEventParams;

Remarks

If the connection is broken normally, StatusCode is 0 and Description is "OK".

If the connection is broken for any other reason, StatusCode has the error code returned by the TCP/IP subsystem. Description contains a description of this code. The value of StatusCode is equal to the value of the TCP/IP error.

Please refer to the Error Messages section for more information.

 
 
Copyright (c) 2019 /n software inc. - All rights reserved.