Warning Event

Fires whenever a validation warning is encountered.

Syntax

public void fireWarning(EdiwriterWarningEvent event);

public class EdiwriterWarningEvent {
  public int warnCode;
  public String message;
  public int segmentNumber;
  public String segmentTag;
  public String segmentErrorCode;
  public String elementErrorCode;
  public int elementPosition;
}

Remarks

The Warning event will fire if a validation error is encountered when writing a new segment to the output document. The WarnCode parameter contains the type of warning encountered. Message is a textual description of the problem. SegmentNumber is the index of the segment where the problem was found.

Possible WarnCode values are:

0 The component is not required but is present.
1 Invalid segment count.
2 Invalid transaction count.
3 Invalid group count.
4 Invalid interchange control number.
5 Invalid group control number.
6 Invalid transaction control number.
10 A required data element is missing.
11 Invalid field length.
12 Invalid field value.
13 A required component is missing.
14 The data element is not defined but is present.
30 Required segment is missing.
31 Required loop is missing.
32 Occurrences exceeds the schema defined limit.
33 Occurrences is less than the schema defined minimum.
40 Paired rule validation failed, the pair of elements must be present.
41 At least one of element is required, see message for list of elements.
42 Exclusion validation failed, only one of the elements can be present.
43 Conditional rule validation failed.
44 List conditional rule validation failed.
45 First, then non validation failed.
46 Only one or none of the elements can be present.

 
 