OutgoingHeartbeat Property
Specifies the class-to-server heartbeat timing.
Syntax
stomp.getOutgoingHeartbeat([callback]) stomp.setOutgoingHeartbeat( outgoingHeartbeat, [callback])
Default Value
0
Callback
The 'callback' parameter specifies a function which will be called when the operation completes (or an error is encountered). If the 'callback' parameter is not specified, then the method will block and will not return until the operation completes (or an error is encountered).
The callback for the getOutgoingHeartbeat([callback]) method is defined as:
function(err, data){ }
'err' is the error that occurred. If there was no error, then 'err' is 'null'.
'data' is the value returned by the method.
The callback for the setOutgoingHeartbeat([callback]) method is defined as:
function(err){ }
'err' is the error that occurred. If there was no error, then 'err' is 'null'.
'err' has 2 properties which hold detailed information:
err.code err.message
Remarks
This property specifies the outgoing heartbeat interval, which is the number of seconds without any class-to-server communication that the class will allow to elapse before sending the server a heartbeat (keepalive). If set to 0 (default), outgoing heartbeats are disabled.
For information about incoming (server-to-class) heartbeats; see the IncomingHeartbeat property.
Before Connecting
Before connecting, this property is used to specify the minimum supported outgoing heartbeat interval (in seconds). By default, this property is set to 0 (no heartbeat).
During the connection process, the minimum outgoing heartbeat interval supported by the class is compared to the interval requested by the server, and the larger of the two values is selected. If one or both sides supply 0 as their value, then no class-to-server heartbeats will be sent.
After Connecting
After connecting, this property cannot be set. Instead, it reflects the outgoing heartbeat interval agreed upon by the class and the server during the connection process.
As the outgoing heartbeat interval negotiation notes above imply, it is possible that the agreed-upon outgoing heartbeat interval may either be larger than the class's supported minimum, or may be 0 (i.e., outgoing heartbeats are disabled).
This property is not available at design time.
Data Type