X12Writer Control

Properties   Methods   Events   Config Settings   Errors  

The X12Writer control is optimized for X12 documents, providing a simple way to create X12 documents.

Syntax

X12Writer

Remarks

The control allows you to create a document from scratch. The control allows you to create an EDI document one segment at a time. Here's how a document would normally be created:

  1. Call LoadSchema to load the necessary schemas for the transactions that will be used.
  2. Specify where to write the output document by setting the OutputFile property or SetOutputStream method, or set neither and check the OutputData property.
  3. Create a new interchange start segment using the StartInterchangeHeader method and set its properties using WriteElementString and WriteComponentString.
  4. To write a basic element value to the current location, call the WriteElementString method. For complex element values, there are two possibilities, elements which are split into components, and elements which repeat. To write these complex element values, use the StartElement and EndElement methods, with WriteComponentString and RepeatElement methods for writing the values. (Examples available below).
  5. Create a new functional group using StartFunctionalGroupHeader and set its properties using WriteElementString and WriteComponentString.
  6. Create a new transaction using StartTransactionHeader and set the properties for the header segment.
  7. Write all the data for the transaction by creating new data segments using StartSegment and providing the path of the segment to create using the schema names of the loops and segments, like /N1Loop1/N1.
  8. Once you are done with the segment, call EndSegment.
  9. Once you are done with the transaction, call CreateTransactionFooter.
  10. Once you are done with the functional group, call CreateFunctionalGroupFooter.
  11. Once the interchange is complete, call CreateInterchangeFooter.

Example X12Writer Code:

//Create an 810 //Start Interchange Header writer.StartInterchangeHeader("004010"); writer.WriteElementString("00"); writer.SkipElement(); writer.WriteElementString("00"); writer.SkipElement(); writer.WriteElementString("ZZ"); writer.WriteElementString("ACME "); writer.WriteElementString("ZZ"); writer.WriteElementString("WAYNE_TECH "); writer.WriteElementString("160707"); writer.WriteElementString("1544"); writer.WriteElementString("U"); writer.WriteElementString("00401"); writer.WriteElementString("000000006"); writer.WriteElementString("0"); writer.WriteElementString("T"); writer.WriteElementString(">"); //Start Functional Group writer.StartFunctionalGroupHeader(); writer.WriteElementString("IN"); writer.WriteElementString("ACME"); writer.WriteElementString("WAYNE_TECH"); writer.WriteElementString("20160707"); writer.WriteElementString("1544"); writer.WriteElementString("6"); writer.WriteElementString("T"); writer.WriteElementString("004010"); //Start Transaction Header writer.StartTransactionHeader("810"); writer.WriteElementString("810"); writer.WriteElementString("0001"); //Write the BIG segment writer.StartSegment("BIG"); writer.WriteElementString("20150708"); writer.WriteElementString("3003014445"); writer.SkipElement(); writer.WriteElementString("0476553272"); writer.SkipElement(); writer.SkipElement(); writer.WriteElementString("DR"); writer.EndElement(); //Write the CUR segment writer.StartSegment("CUR"); writer.WriteElementString("SE"); writer.WriteElementString("USD"); //Write the REF segment writer.StartSegment("REF"); writer.WriteElementString("8M"); writer.WriteElementString("0056");

Property List


The following is the full list of the properties of the control with short descriptions. Click on the links for further details.

FileWriteModeControls how the output file is opened.
OutputDataContains the output data.
OutputFileSpecifies the name of the EDI file to write to.
SchemaFormatThe format of the schema file.
SuffixWhat to append after each segment delimiter.

Method List


The following is the full list of the methods of the control with short descriptions. Click on the links for further details.

CompileSchemaCompiles an existing XSD schema into an optimized binary representation.
ConfigSets or retrieves a configuration setting.
CreateFunctionalGroupFooterCloses the current functional group by writing its footer segment.
CreateInterchangeFooterCloses the current interchange by writing its footer segment.
CreateTransactionFooterCloses the current transaction set by writing its footer segment.
DisplaySchemaInfoReturns a string showing the structure of the schema defining the document.
EndElementFinishes the current composite data element.
EndSegmentEnds writing the current segment.
FlushForces any pending segments to be written to the output stream without closing it.
LoadSchemaLoads a schema file describing a Transaction Set.
RepeatElementAdds a new repetition to the current element.
ResetResets the state of the control.
SkipComponentMoves to the next sub-element in the current composite element in the current segment.
SkipElementMoves to the next data element in the current segment.
StartElementStarts a new EDI composite data element on the current segment.
StartFunctionalGroupHeaderCreates a new EDI functional group header segment on the current document.
StartInterchangeHeaderCreates a new EDI Interchange header segment on the current document.
StartSegmentCreates a new EDI data segment on the current document.
StartTransactionHeaderCreates a new EDI transaction set header on the current document.
WriteComponentStringSets the value of the next control within the current element in the current segment.
WriteElementStringSets a value of the next element in the current segment to a simple value.
WriteTransactionWrites an entire transaction to the output.

Event List


The following is the full list of the events fired by the control with short descriptions. Click on the links for further details.

ErrorFired when information is available about errors during data delivery.
OutputFires whenever a segment is complete.
WarningFires whenever a validation warning is encountered.

Config Settings


The following is a list of config settings for the control with short descriptions. Click on the links for further details.

ComponentDelimiterThe delimiter character to use to separate controls.
EdifactSyntaxVersionChanges the syntax version used for EDIFACT control segments.
EDIStandardThe document format.
ElementDelimiterThe delimiter character to use to separate data elements.
EncodingThe character encoding to be applied when reading and writing data.
IncludeUNAWhether to include the UNA segment in the output.
ReleaseCharThe character to use to escape delimiters within values.
RepetitionCharThe repetition character.
SegmentDelimiterThe delimiter character to use to separate segments.
StrictSchemaValidationSpecifies the behavior during schema validation.
TransactionOnlyIgnores interchange and functional group validation, allowing you to build the transaction body.
CodePageThe system code page used for Unicode to Multibyte translations.
MaskSensitiveWhether sensitive data is masked in log messages.
UseInternalSecurityAPIWhether or not to use the system security libraries or an internal implementation.

FileWriteMode Property (X12Writer Control)

Controls how the output file is opened.

Syntax

x12writercontrol.FileWriteMode[=integer]

Possible Values

fwmCreate(0), 
fwmOverwrite(1), 
fwmAppend(2)

Default Value

0

Remarks

This property controls how the component will open the output file specified in OutputFile. Possible values are:

fwmCreate (0)Always create a new file. If the file already exists, an error will be raised.
fwmOverwrite (1)If the output file already exists, it will be overwritten.
fwmAppend (2)If the output file already exists, data will be appended to it.

Data Type

Integer

OutputData Property (X12Writer Control)

Contains the output data.

Syntax

x12writercontrol.OutputData

Default Value

""

Remarks

This property will be populated with the contents of the EDI data as output by the control when no OutputFile has been specified and SetOutputStream has not been called with a valid output stream.

To read or write binary data to the property, a Variant (Byte Array) version is provided in .OutputDataB.

This property is read-only.

Data Type

Binary String

OutputFile Property (X12Writer Control)

Specifies the name of the EDI file to write to.

Syntax

x12writercontrol.OutputFile[=string]

Default Value

""

Remarks

Set OutputFile before calling the StartInterchangeHeader method to write an EDI interchange to a file on disk.

Data Type

String

SchemaFormat Property (X12Writer Control)

The format of the schema file.

Syntax

x12writercontrol.SchemaFormat[=integer]

Possible Values

schemaAutomatic(0), 
schemaBinary(1), 
schemaBizTalk(2), 
schemaSEF(3), 
schemaBOTS(4), 
schemaAltova(5), 
schemaJSON(6)

Default Value

0

Remarks

Set SchemaFormat before calling the LoadSchema method to specify the loading schema format.

The following schema formats are supported:

0 (schemaAutomatic - default) The schema type is automatically determined based on file extension.
1 (schemaBinary) A binary schema that was previously compiled by calling CompileSchema.
2 (schemaBizTalk) BizTalk (XSD): http://msdn.microsoft.com/en-us/library/aa559426(v=BTS.70).aspx
3 (schemaSEF) TIBCO Standard Exchange Format (SEF): https://docs.tibco.com/products/tibco-foresight-edisim-6-18-0
5 (schemaAltova) Altova: http://www.altova.com/
6 (schemaJSON) JSON

Data Type

Integer

Suffix Property (X12Writer Control)

What to append after each segment delimiter.

Syntax

x12writercontrol.Suffix[=integer]

Possible Values

suffixNone(0), 
suffixCR(1), 
suffixLF(2), 
suffixCRLF(3)

Default Value

0

Remarks

If Suffix is different from suffixNone, trailing (suffix) characters are appended after each segment delimiter. This is useful if you want to have a carriage return/line feed after each segment to make the document more readable.

This property is not available at design time.

Data Type

Integer

CompileSchema Method (X12Writer Control)

Compiles an existing XSD schema into an optimized binary representation.

Syntax

x12writercontrol.CompileSchema XsdSchema, BinSchema

Remarks

This method parses XsdSchema and generates an optimized binary representation that is saved into the path referenced by BinSchema. Binary schemas are smaller and require less resources when loading later using LoadSchema

If the schema file does not exists or cannot be parsed as an EDI schema, the component throws an exception.

Config Method (X12Writer Control)

Sets or retrieves a configuration setting.

Syntax

x12writercontrol.Config ConfigurationString

Remarks

Config is a generic method available in every control. It is used to set and retrieve configuration settings for the control.

These settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.

To set a configuration setting named PROPERTY, you must call Config("PROPERTY=VALUE"), where VALUE is the value of the setting expressed as a string. For boolean values, use the strings "True", "False", "0", "1", "Yes", or "No" (case does not matter).

To read (query) the value of a configuration setting, you must call Config("PROPERTY"). The value will be returned as a string.

CreateFunctionalGroupFooter Method (X12Writer Control)

Closes the current functional group by writing its footer segment.

Syntax

x12writercontrol.CreateFunctionalGroupFooter 

Remarks

The CreateFunctionalGroupFooter method will write any existing segments to the output stream and then generate and write the functional group closing segment (GE or UNE). If there is an open transaction set, CreateFunctionalGroupFooter will first call CreateTransactionFooter to close it. If there is no functional group open, an exception will be thrown.

CreateInterchangeFooter Method (X12Writer Control)

Closes the current interchange by writing its footer segment.

Syntax

x12writercontrol.CreateInterchangeFooter 

Remarks

The CreateInterchangeFooter method will write any existing segments to the output stream and then generate and write the interchange closing segment (IEA or UNZ). If there is an open transaction set, CreateInterchangeFooter will first call CreateTransactionFooter to close it. If there is an open functional group, CreateInterchangeFooter will first call CreateFunctionalGroupFooter to close it. If there is no interchange open, an exception will be thrown.

CreateTransactionFooter Method (X12Writer Control)

Closes the current transaction set by writing its footer segment.

Syntax

x12writercontrol.CreateTransactionFooter 

Remarks

The CreateTransactionFooter method will write any existing segments to the output stream and then generate and write the transaction set closing segment (SE or UNT). If there are no open transaction sets, an exception will be thrown.

DisplaySchemaInfo Method (X12Writer Control)

Returns a string showing the structure of the schema defining the document.

Syntax

x12writercontrol.DisplaySchemaInfo 

Remarks

After calling LoadSchema this may be called to obtain information about the structure of the schema defining the document. If the desired XPath is not known this helps determine the structure so that the correct XPath can be built.

Note: A valid schema must be loaded via LoadSchema.

For instance: Console.WriteLine(component.DisplaySchemaInfo()); Will output text like:

UNH[0,1]
  BGM[0,1]
  DTM[0,35]
  PAI[0,1]
  ALI[0,5]
  IMD[0,1]
  FTX[0,10]
  LOC[0,10]
  GIS[0,10]
  DGS[0,1]
  RFFLoop1[0,99]
    RFF[0,1]
    DTM_2[0,5]
    GIR[0,5]
    LOC_2[0,2]
    MEA[0,5]
    QTY[0,2]
    FTX_2[0,5]
    MOA[0,2]
  NADLoop1[0,99]
    NAD[0,1]
    LOC_3[0,25]
    FII[0,5]
    RFFLoop2[0,9999]
      RFF_2[0,1]
      DTM_3[0,5]
    DOCLoop1[0,5]
      DOC[0,1]
      DTM_4[0,5]
    CTALoop1[0,5]
      CTA[0,1]
      COM[0,5]
  TAXLoop1[0,5]
    TAX[0,1]
    MOA_2[0,1]
    LOC_4[0,5]
  CUXLoop1[0,5]
    CUX[0,1]
    DTM_5[0,5]
  PATLoop1[0,10]
    PAT[0,1]
    DTM_6[0,5]
    PCD[0,1]
    MOA_3[0,1]
    PAI_2[0,1]
    FII_2[0,1]
  TDTLoop1[0,10]
    TDT[0,1]
    TSR[0,1]
    LOCLoop1[0,10]
      LOC_5[0,1]
      DTM_7[0,5]
    RFFLoop3[0,9999]
      RFF_3[0,1]
      DTM_8[0,5]
  TODLoop1[0,5]
    TOD[0,1]
    LOC_6[0,2]
  PACLoop1[0,1000]
    PAC[0,1]
    MEA_2[0,5]
    EQD[0,1]
    PCILoop1[0,5]
      PCI[0,1]
      RFF_4[0,1]
      DTM_9[0,5]
      GIN[0,5]
  ALCLoop1[0,9999]
    ALC[0,1]
    ALI_2[0,5]
    FTX_3[0,1]
    RFFLoop4[0,5]
      RFF_5[0,1]
      DTM_10[0,5]
    QTYLoop1[0,1]
      QTY_2[0,1]
      RNG[0,1]
    PCDLoop1[0,1]
      PCD_2[0,1]
      RNG_2[0,1]
    MOALoop1[0,2]
      MOA_4[0,1]
      RNG_3[0,1]
      CUX_2[0,1]
      DTM_11[0,1]
    RTELoop1[0,1]
      RTE[0,1]
      RNG_4[0,1]
    TAXLoop2[0,5]
      TAX_2[0,1]
      MOA_5[0,1]
  RCSLoop1[0,100]
    RCS[0,1]
    RFF_6[0,5]
    DTM_12[0,5]
    FTX_4[0,5]
  AJTLoop1[0,1]
    AJT[0,1]
    FTX_5[0,5]
  INPLoop1[0,1]
    INP[0,1]
    FTX_6[0,5]
  LINLoop1[0,9999999]
    LIN[0,1]
    PIA[0,25]
    IMD_2[0,10]
    MEA_3[0,5]
    QTY_3[0,5]
    PCD_3[0,1]
    ALI_3[0,5]
    DTM_13[0,35]
    GIN_2[0,1000]
    GIR_2[0,1000]
    QVR[0,1]
    EQD_2[0,1]
    FTX_7[0,5]
    DGS_2[0,1]
    MOALoop2[0,10]
      MOA_6[0,1]
      CUX_3[0,1]
    PATLoop2[0,10]
      PAT_2[0,1]
      DTM_14[0,5]
      PCD_4[0,1]
      MOA_7[0,1]
    PRILoop1[0,25]
      PRI[0,1]
      CUX_4[0,1]
      APR[0,1]
      RNG_5[0,1]
      DTM_15[0,5]
    RFFLoop5[0,10]
      RFF_7[0,1]
      DTM_16[0,5]
    PACLoop2[0,10]
      PAC_2[0,1]
      MEA_4[0,10]
      EQD_3[0,1]
      PCILoop2[0,10]
        PCI_2[0,1]
        RFF_8[0,1]
        DTM_17[0,5]
        GIN_3[0,10]
    LOCLoop2[0,9999]
      LOC_7[0,1]
      QTY_4[0,100]
      DTM_18[0,5]
    TAXLoop3[0,99]
      TAX_3[0,1]
      MOA_8[0,1]
      LOC_8[0,5]
    NADLoop2[0,99]
      NAD_2[0,1]
      LOC_9[0,5]
      RFFLoop6[0,5]
        RFF_9[0,1]
        DTM_19[0,5]
      DOCLoop2[0,5]
        DOC_2[0,1]
        DTM_20[0,5]
      CTALoop2[0,5]
        CTA_2[0,1]
        COM_2[0,5]
    ALCLoop2[0,30]
      ALC_2[0,1]
      ALI_4[0,5]
      DTM_21[0,5]
      FTX_8[0,1]
      QTYLoop2[0,1]
        QTY_5[0,1]
        RNG_6[0,1]
      PCDLoop2[0,1]
        PCD_5[0,1]
        RNG_7[0,1]
      MOALoop3[0,2]
        MOA_9[0,1]
        RNG_8[0,1]
        CUX_5[0,1]
        DTM_22[0,1]
      RTELoop2[0,1]
        RTE_2[0,1]
        RNG_9[0,1]
      TAXLoop4[0,5]
        TAX_4[0,1]
        MOA_10[0,1]
    TDTLoop2[0,10]
      TDT_2[0,1]
      LOCLoop3[0,10]
        LOC_10[0,1]
        DTM_23[0,5]
    TODLoop2[0,5]
      TOD_2[0,1]
      LOC_11[0,2]
    RCSLoop2[0,100]
      RCS_2[0,1]
      RFF_10[0,5]
      DTM_24[0,5]
      FTX_9[0,5]
    GISLoop1[0,10]
      GIS_2[0,1]
      RFF_11[0,1]
      DTM_25[0,5]
      GIR_3[0,5]
      LOC_12[0,2]
      MEA_5[0,5]
      QTY_6[0,2]
      FTX_10[0,5]
      MOA_11[0,2]
  UNS[0,1]
  CNT[0,10]
  MOALoop4[0,100]
    MOA_12[0,1]
    RFFLoop7[0,1]
      RFF_12[0,1]
      DTM_26[0,5]
  TAXLoop5[0,10]
    TAX_5[0,1]
    MOA_13[0,2]
  ALCLoop3[0,15]
    ALC_3[0,1]
    ALI_5[0,1]
    MOA_14[0,2]
    FTX_11[0,1]
  UNT[0,1]

EndElement Method (X12Writer Control)

Finishes the current composite data element.

Syntax

x12writercontrol.EndElement 

Remarks

Call EndElement once you've written all components in an element started with StartElement. You should not call this if you wrote a simple element using WriteElementString

EndSegment Method (X12Writer Control)

Ends writing the current segment.

Syntax

x12writercontrol.EndSegment 

Remarks

EndSegment terminates writing the current segment and flushes it to the output stream/file.

You should call EndSegment to close a segment started with StartSegment, StartInterchangeHeader, StartFunctionalGroupHeader or StartTransactionHeader.

Flush Method (X12Writer Control)

Forces any pending segments to be written to the output stream without closing it.

Syntax

x12writercontrol.Flush 

Remarks

The Flush method forces the component to write the last created segment to the output stream and then flush the output stream.

LoadSchema Method (X12Writer Control)

Loads a schema file describing a Transaction Set.

Syntax

x12writercontrol.LoadSchema FileName

Remarks

This method parses the File and loads it into an internal schema list. The control will attempt to automatically detect the SchemaFormat.

If the schema file does not exist or cannot be parsed as an EDI schema, the control fails with an error.

RepeatElement Method (X12Writer Control)

Adds a new repetition to the current element.

Syntax

x12writercontrol.RepeatElement 

Remarks

RepeatElement is used to write repeated data elements in supporting version of X12 or EDIFACT. To use it, first write the first repetition of the simple or composite data element and then call RepeatElement to repeat it, then write again.

Example: Repeating a simple data element: EDIWriter writer = new EDIWriter(); ... writer.StartSegment("Tag"); ... writer.WriteElementString("R1_1"); writer.RepeatElement(); writer.WriteElementString("R1_2"); writer.RepeatElement(); writer.WriteElementString("R1_3"); ... writer.EndSegment();

Example: Repeating a composite data element: EDIWriter writer = new EDIWriter(); ... writer.StartSegment("Tag"); ... writer.StartElement(); writer.WriteComponentString("C1_1"); writer.WriteComponentString("C2_1"); writer.RepeatElement(); writer.WriteComponentString("C1_2"); writer.WriteComponentString("C2_2"); writer.RepeatElement(); writer.WriteComponentString("C1_3"); writer.EndElement(); ... writer.EndSegment();

Reset Method (X12Writer Control)

Resets the state of the control.

Syntax

x12writercontrol.Reset 

Remarks

Resets the state of the writer. If a document has been partially written already, it will not be closed correctly and the write process will be aborted.

SkipComponent Method (X12Writer Control)

Moves to the next sub-element in the current composite element in the current segment.

Syntax

x12writercontrol.SkipComponent 

Remarks

SkipComponent can be used to avoid providing a value for the current sub-element in the opened composite element within the current segment.

If the sub-element already has a value (such as one provided by default by the control), said value will not be overwritten.

SkipElement Method (X12Writer Control)

Moves to the next data element in the current segment.

Syntax

x12writercontrol.SkipElement 

Remarks

SkipElement can be used to avoid providing a value for the current element in the current segment.

If the element already has a value (such as one provided by default by the control), said value will not be overwritten.

StartElement Method (X12Writer Control)

Starts a new EDI composite data element on the current segment.

Syntax

x12writercontrol.StartElement 

Remarks

When called, a new composite data element is created in the current segment. You can then call WriteComponentString one or more times to write the individual components or subelements that make up this composite.

Call EndElement once you've written all components in this element.

StartFunctionalGroupHeader Method (X12Writer Control)

Creates a new EDI functional group header segment on the current document.

Syntax

x12writercontrol.StartFunctionalGroupHeader 

Remarks

When called, a new functional group start (GS or UNG) segment is created and set as the current segment. You should then set the values on said segment before adding a new transaction set within the document.

StartInterchangeHeader Method (X12Writer Control)

Creates a new EDI Interchange header segment on the current document.

Syntax

x12writercontrol.StartInterchangeHeader Version

Remarks

When called, a new interchange start (ISA or UNB) segment is created and set as the current segment. You should then set the values on said segment before creating a functional group or a new transaction set within the document.

StartSegment Method (X12Writer Control)

Creates a new EDI data segment on the current document.

Syntax

x12writercontrol.StartSegment SegmentType

Remarks

When called, a new data segment is created in the current transaction and set as the current segment. You can then set the values on said segment. Creating a new data segment automatically writes the previous current segment to the output stream.

The SegmentType argument specifies the type of data segment to create, using an XPath-like syntax, based on the transaction set schema. For example, to create a new N1 segment on the first N1 loop, specify "/N1Loop1/N1".

It's important to realize that segments must be created in the same order they should appear on the target EDI document. The EDIWriter component doesn't automatically enforce ordering rules, nor does it force the document to reorder segments in loops automatically.

StartTransactionHeader Method (X12Writer Control)

Creates a new EDI transaction set header on the current document.

Syntax

x12writercontrol.StartTransactionHeader Code

Remarks

When called, a new transaction set start (ST or UNH) segment is created and set as the current segment. You should then set the values on said segment before adding creating transaction data segments.

The Code argument should specify the transaction code you want to create (for example, "850" or "INVOIC"). This value, together with the EDI specification and the version provided in the StartInterchangeHeader method are used to locate a matching transaction set schema on the components schema cache. You must make sure that a corresponding schema has been successfully loaded into the component by using the LoadSchema method before trying to call StartTransactionHeader.

WriteComponentString Method (X12Writer Control)

Sets the value of the next control within the current element in the current segment.

Syntax

x12writercontrol.WriteComponentString Value

Remarks

Use the WriteComponentString method to specify a value for an individual component within a composite data element.

To write an entire composite data element, first call the StartElement method, then do one or more calls to WriteComponentString. Finish the composite element by calling the EndElement method.

WriteElementString Method (X12Writer Control)

Sets a value of the next element in the current segment to a simple value.

Syntax

x12writercontrol.WriteElementString Value

Remarks

Use the WriteElementString method to specify a value for the next data element with simple content on the current segment.

To write a composite data element, even if it has a single sub-element, use the StartElement and WriteComponentString methods instead.

WriteTransaction Method (X12Writer Control)

Writes an entire transaction to the output.

Syntax

x12writercontrol.WriteTransaction Value

Remarks

Use the WriteTransaction method when you have generated a complete transaction outside of the control and want to include it in the document being created by this instance.

No validation is done on the contents of the Value parameter. You must ensure the transaction data is valid and matches the same conventions (delimiters, etc) being used in this document.

Error Event (X12Writer Control)

Fired when information is available about errors during data delivery.

Syntax

Sub x12writercontrol_Error(ErrorCode As Integer, Description As String)

Remarks

The Error event is fired in case of exceptional conditions during message processing. Normally the control fails with an error.

The ErrorCode parameter contains an error code, and the Description parameter contains a textual description of the error. For a list of valid error codes and their descriptions, please refer to the Error Codes section.

Output Event (X12Writer Control)

Fires whenever a segment is complete.

Syntax

Sub x12writercontrol_Output(OutputData As String)

Remarks

The Output event will fire when the writer completes a new segment and writes data to the output stream or buffer. The Data parameter contains the data bytes.

Warning Event (X12Writer Control)

Fires whenever a validation warning is encountered.

Syntax

Sub x12writercontrol_Warning(WarnCode As Integer, Message As String, SegmentNumber As Integer, SegmentTag As String, SegmentErrorCode As String, ElementErrorCode As String, ElementPosition As Integer)

Remarks

The Warning event will fire if a validation error is encountered when writing a new segment to the output document. The WarnCode parameter contains the type of warning encountered. Message is a textual description of the problem. SegmentNumber is the index of the segment where the problem was found.

0 The component is not required but is present.
1 Invalid segment count.
2 Invalid transaction count.
3 Invalid group count.
4 Invalid interchange control number.
5 Invalid group control number.
6 Invalid transaction control number.
10 A required data element is missing.
11 Invalid field length.
12 Invalid field value.
13 A required component is missing.
14 The data element is not defined but is present.
30 Required segment is missing.
31 Required loop is missing.
32 Occurrences exceeds the schema defined limit.
33 Occurrences is less than the schema defined minimum.
40 Paired rule validation failed, the pair of elements must be present.
41 At least one of element is required, see message for list of elements.
42 Exclusion validation failed, only one of the elements can be present.
43 Conditional rule validation failed.
44 List conditional rule validation failed.
45 First then none validation failed. The presence of an element requires that other specific elements must not be present.
46 Only one or none of the elements can be present.

Config Settings (X12Writer Control)

The control accepts one or more of the following configuration settings. Configuration settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.

X12Writer Config Settings

ComponentDelimiter:   The delimiter character to use to separate components.

When set, this changes the default delimiter to use to separate components within a data element. The default value depends on the EDI specification being used.

EdifactSyntaxVersion:   Changes the syntax version used for EDIFACT control segments.

Can be a number from 1 to 4. The default value is 1.

EDIStandard:   The document format.

This property specifies standard that the document follows. Possible values are:

  • 1 (EDIFACT - default)
  • 3 (TRADACOMS)

ElementDelimiter:   The delimiter character to use to separate data elements.

When set, this changes the default delimiter to use to separate data elements within a segment. The default value depends on the EDI specification being used.

Encoding:   The character encoding to be applied when reading and writing data.

If the data contains non-ASCII characters this setting should be specified so characters are properly preserved. This value should be set to a valid character set such as "UTF-8" or "ISO-8859-1".

IncludeUNA:   Whether to include the UNA segment in the output.

This setting determines whether the UNA segment is included in the EDIFACT output. If False, no Service String Advice (UNA) segment will be generated for EDIFACT interchanges. The default value is True.

ReleaseChar:   The character to use to escape delimiters within values.

When set, this changes the default escape character. The default value depends on the EDI specification being used.

RepetitionChar:   The repetition character.

When set, this changes the default repetition character. The default value depends on the EDI specification being used.

SegmentDelimiter:   The delimiter character to use to separate segments.

When set, this changes the default delimiter to use to separate segments within an EDI document. The default value depends on the EDI specification being used.

StrictSchemaValidation:   Specifies the behavior during schema validation.

This setting specifies what happens when performing schema validation and a validation warning occurs. By default this value is set to 1 (Warn) and the Warning event will fire, but processing will not stop. See the WarnCode parameter list in the Warning event for details about possible validation warnings. Possible values for this setting are:

0 (Ignore) All validation warnings will be ignored. Warning will not fire with warnings.
1 (Warn - default) The Warning event will fire with all validation warnings.
2 (Error) All validation warnings are treated as errors and will cause an exception. Processing will stop immediately.
TransactionOnly:   Ignores interchange and functional group validation, allowing you to build the transaction body.

When set to true, interchange and functional group headers will not be required. This allows building of the transaction level of an EDIFact document without specifying a document type.

Base Config Settings

CodePage:   The system code page used for Unicode to Multibyte translations.

The default code page is Unicode UTF-8 (65001).

The following is a list of valid code page identifiers:

IdentifierName
037IBM EBCDIC - U.S./Canada
437OEM - United States
500IBM EBCDIC - International
708Arabic - ASMO 708
709Arabic - ASMO 449+, BCON V4
710Arabic - Transparent Arabic
720Arabic - Transparent ASMO
737OEM - Greek (formerly 437G)
775OEM - Baltic
850OEM - Multilingual Latin I
852OEM - Latin II
855OEM - Cyrillic (primarily Russian)
857OEM - Turkish
858OEM - Multilingual Latin I + Euro symbol
860OEM - Portuguese
861OEM - Icelandic
862OEM - Hebrew
863OEM - Canadian-French
864OEM - Arabic
865OEM - Nordic
866OEM - Russian
869OEM - Modern Greek
870IBM EBCDIC - Multilingual/ROECE (Latin-2)
874ANSI/OEM - Thai (same as 28605, ISO 8859-15)
875IBM EBCDIC - Modern Greek
932ANSI/OEM - Japanese, Shift-JIS
936ANSI/OEM - Simplified Chinese (PRC, Singapore)
949ANSI/OEM - Korean (Unified Hangul Code)
950ANSI/OEM - Traditional Chinese (Taiwan; Hong Kong SAR, PRC)
1026IBM EBCDIC - Turkish (Latin-5)
1047IBM EBCDIC - Latin 1/Open System
1140IBM EBCDIC - U.S./Canada (037 + Euro symbol)
1141IBM EBCDIC - Germany (20273 + Euro symbol)
1142IBM EBCDIC - Denmark/Norway (20277 + Euro symbol)
1143IBM EBCDIC - Finland/Sweden (20278 + Euro symbol)
1144IBM EBCDIC - Italy (20280 + Euro symbol)
1145IBM EBCDIC - Latin America/Spain (20284 + Euro symbol)
1146IBM EBCDIC - United Kingdom (20285 + Euro symbol)
1147IBM EBCDIC - France (20297 + Euro symbol)
1148IBM EBCDIC - International (500 + Euro symbol)
1149IBM EBCDIC - Icelandic (20871 + Euro symbol)
1200Unicode UCS-2 Little-Endian (BMP of ISO 10646)
1201Unicode UCS-2 Big-Endian
1250ANSI - Central European
1251ANSI - Cyrillic
1252ANSI - Latin I
1253ANSI - Greek
1254ANSI - Turkish
1255ANSI - Hebrew
1256ANSI - Arabic
1257ANSI - Baltic
1258ANSI/OEM - Vietnamese
1361Korean (Johab)
10000MAC - Roman
10001MAC - Japanese
10002MAC - Traditional Chinese (Big5)
10003MAC - Korean
10004MAC - Arabic
10005MAC - Hebrew
10006MAC - Greek I
10007MAC - Cyrillic
10008MAC - Simplified Chinese (GB 2312)
10010MAC - Romania
10017MAC - Ukraine
10021MAC - Thai
10029MAC - Latin II
10079MAC - Icelandic
10081MAC - Turkish
10082MAC - Croatia
12000Unicode UCS-4 Little-Endian
12001Unicode UCS-4 Big-Endian
20000CNS - Taiwan
20001TCA - Taiwan
20002Eten - Taiwan
20003IBM5550 - Taiwan
20004TeleText - Taiwan
20005Wang - Taiwan
20105IA5 IRV International Alphabet No. 5 (7-bit)
20106IA5 German (7-bit)
20107IA5 Swedish (7-bit)
20108IA5 Norwegian (7-bit)
20127US-ASCII (7-bit)
20261T.61
20269ISO 6937 Non-Spacing Accent
20273IBM EBCDIC - Germany
20277IBM EBCDIC - Denmark/Norway
20278IBM EBCDIC - Finland/Sweden
20280IBM EBCDIC - Italy
20284IBM EBCDIC - Latin America/Spain
20285IBM EBCDIC - United Kingdom
20290IBM EBCDIC - Japanese Katakana Extended
20297IBM EBCDIC - France
20420IBM EBCDIC - Arabic
20423IBM EBCDIC - Greek
20424IBM EBCDIC - Hebrew
20833IBM EBCDIC - Korean Extended
20838IBM EBCDIC - Thai
20866Russian - KOI8-R
20871IBM EBCDIC - Icelandic
20880IBM EBCDIC - Cyrillic (Russian)
20905IBM EBCDIC - Turkish
20924IBM EBCDIC - Latin-1/Open System (1047 + Euro symbol)
20932JIS X 0208-1990 & 0121-1990
20936Simplified Chinese (GB2312)
21025IBM EBCDIC - Cyrillic (Serbian, Bulgarian)
21027Extended Alpha Lowercase
21866Ukrainian (KOI8-U)
28591ISO 8859-1 Latin I
28592ISO 8859-2 Central Europe
28593ISO 8859-3 Latin 3
28594ISO 8859-4 Baltic
28595ISO 8859-5 Cyrillic
28596ISO 8859-6 Arabic
28597ISO 8859-7 Greek
28598ISO 8859-8 Hebrew
28599ISO 8859-9 Latin 5
28605ISO 8859-15 Latin 9
29001Europa 3
38598ISO 8859-8 Hebrew
50220ISO 2022 Japanese with no halfwidth Katakana
50221ISO 2022 Japanese with halfwidth Katakana
50222ISO 2022 Japanese JIS X 0201-1989
50225ISO 2022 Korean
50227ISO 2022 Simplified Chinese
50229ISO 2022 Traditional Chinese
50930Japanese (Katakana) Extended
50931US/Canada and Japanese
50933Korean Extended and Korean
50935Simplified Chinese Extended and Simplified Chinese
50936Simplified Chinese
50937US/Canada and Traditional Chinese
50939Japanese (Latin) Extended and Japanese
51932EUC - Japanese
51936EUC - Simplified Chinese
51949EUC - Korean
51950EUC - Traditional Chinese
52936HZ-GB2312 Simplified Chinese
54936Windows XP: GB18030 Simplified Chinese (4 Byte)
57002ISCII Devanagari
57003ISCII Bengali
57004ISCII Tamil
57005ISCII Telugu
57006ISCII Assamese
57007ISCII Oriya
57008ISCII Kannada
57009ISCII Malayalam
57010ISCII Gujarati
57011ISCII Punjabi
65000Unicode UTF-7
65001Unicode UTF-8
The following is a list of valid code page identifiers for Mac OS only:
IdentifierName
1ASCII
2NEXTSTEP
3JapaneseEUC
4UTF8
5ISOLatin1
6Symbol
7NonLossyASCII
8ShiftJIS
9ISOLatin2
10Unicode
11WindowsCP1251
12WindowsCP1252
13WindowsCP1253
14WindowsCP1254
15WindowsCP1250
21ISO2022JP
30MacOSRoman
10UTF16String
0x90000100UTF16BigEndian
0x94000100UTF16LittleEndian
0x8c000100UTF32String
0x98000100UTF32BigEndian
0x9c000100UTF32LittleEndian
65536Proprietary

MaskSensitive:   Whether sensitive data is masked in log messages.

In certain circumstances it may be beneficial to mask sensitive data, like passwords, in log messages. Set this to to mask sensitive data. The default is .

This setting only works on these controls: AS3Receiver, AS3Sender, Atom, Client(3DS), FTP, FTPServer, IMAP, OFTPClient, SSHClient, SCP, Server(3DS), Sexec, SFTP, SFTPServer, SSHServer, TCPClient, TCPServer.

UseInternalSecurityAPI:   Whether or not to use the system security libraries or an internal implementation.

When set to , the control will use the system security libraries by default to perform cryptographic functions where applicable.

Setting this configuration setting to tells the control to use the internal implementation instead of using the system security libraries.

This setting is set to by default on all platforms.

Trappable Errors (X12Writer Control)

X12Writer Errors

21001    Input/Output error
21002    No stream or file name were specified for the component
21003    Unexpected end of file (EOF).
21004    Segment not found.
21005    Segment not found in schema.
21006    Schema not found.
21011    Invalid Writer state.
21012    Segment does not have the specified element or component.
21045    Error while reading schema file.
21100    Unexpected error.