TRADACOMSWriter Class
Properties Methods Events Config Settings Errors
The TRADACOMSWriter class is optimized for TRADACOMS documents, providing a simple way to create TRADACOMS documents.
Syntax
TRADACOMSWriter
Remarks
The class allows you to create a document from scratch. The class allows you to create an EDI document one segment at a time. Here's how a document would normally be created:
- Call LoadSchema to load the necessary schemas for the transactions that will be used.
- Specify where to write the output document by setting the OutputFile property or SetOutputStream method, or set neither and check the OutputData property.
- Create a new interchange start segment using the StartInterchangeHeader method and set its properties using WriteElementString and WriteComponentString.
- To write a basic element value to the current location, call the WriteElementString method. For complex element values, there are two possibilities, elements which are split into components, and elements which repeat. To write these complex element values, use the StartElement and EndElement methods, with WriteComponentString and RepeatElement methods for writing the values. (Examples available below).
- Create a new functional group using StartFunctionalGroupHeader and set its properties using WriteElementString and WriteComponentString.
- Create a new transaction using StartTransactionHeader and set the properties for the header segment.
- Write all the data for the transaction by creating new data segments using StartSegment and providing the path of the segment to create using the schema names of the loops and segments, like /N1Loop1/N1.
- Once you are done with the segment, call EndSegment.
- Once you are done with the transaction, call CreateTransactionFooter.
- Once you are done with the functional group, call CreateFunctionalGroupFooter.
- Once the interchange is complete, call CreateInterchangeFooter.
Example EDIFACTWriter Code:
EDIWriter1.StartInterchangeHeader("D98B");
//Complex Element, two components
EDIWriter1.StartElement();
EDIWriter1.WriteComponentString("UNOB");
EDIWriter1.WriteComponentString("1");
EDIWriter1.EndElement();
//Skip a value for this element
EDIWriter1.SkipElement();
//Basic element
EDIWriter1.WriteElementString("7654323");
...
EDIWriter1.StartFunctionalGroupHeader();
...
EDIWriter1.StartTransactionHeader("APERAK");
//Complex Element, repeated element
EDIWriter1.StartElement();
EDIWriter1.WriteComponentString("UNH1");
EDIWriter1.RepeatElement();
EDIWriter1.WriteComponentString("UNH2");
EDIWriter1.EndElement();
...
//Segment and its data
EDIWriter1.StartSegment("BGM");
EDIWriter1.StartElement();
EDIWriter1.WriteComponentString("C00");
EDIWriter1.EndElement();
EDIWriter1.StartElement();
EDIWriter1.WriteComponentString("C10601");
EDIWriter1.EndElement();
EDIWriter1.EndSegment();
...
CreateTransactionFooter();
CreateFunctionalGroupFooter();
CreateInterchangeFooter();
Property List
The following is the full list of the properties of the class with short descriptions. Click on the links for further details.
FileWriteMode | Controls how the output file is opened. |
OutputData | Contains the output data. |
OutputFile | Specifies the name of the EDI file to write to. |
SchemaFormat | The format of the schema file. |
Suffix | What to append after each segment delimiter. |
Method List
The following is the full list of the methods of the class with short descriptions. Click on the links for further details.
CompileSchema | Compiles an existing XSD schema into an optimized binary representation. |
Config | Sets or retrieves a configuration setting. |
CreateFunctionalGroupFooter | Closes the current functional group by writing its footer segment. |
CreateInterchangeFooter | Closes the current interchange by writing its footer segment. |
CreateTransactionFooter | Closes the current transaction set by writing its footer segment. |
DisplaySchemaInfo | Returns a string showing the structure of the schema defining the document. |
EndElement | Finishes the current composite data element. |
EndSegment | Ends writing the current segment. |
Flush | Forces any pending segments to be written to the output stream without closing it. |
LoadSchema | Loads a schema file describing a Transaction Set. |
RepeatElement | Adds a new repetition to the current element. |
Reset | Resets the state of the control. |
SkipComponent | Moves to the next sub-element in the current composite element in the current segment. |
SkipElement | Moves to the next data element in the current segment. |
StartElement | Starts a new EDI composite data element on the current segment. |
StartFunctionalGroupHeader | Creates a new EDI functional group header segment on the current document. |
StartInterchangeHeader | Creates a new EDI Interchange header segment on the current document. |
StartSegment | Creates a new EDI data segment on the current document. |
StartTransactionHeader | Creates a new EDI transaction set header on the current document. |
WriteComponentString | Sets the value of the next class within the current element in the current segment. |
WriteElementString | Sets a value of the next element in the current segment to a simple value. |
WriteTransaction | Writes an entire transaction to the output. |
Event List
The following is the full list of the events fired by the class with short descriptions. Click on the links for further details.
Error | Fired when information is available about errors during data delivery. |
Output | Fires whenever a segment is complete. |
Warning | Fires whenever a validation warning is encountered. |
Config Settings
The following is a list of config settings for the class with short descriptions. Click on the links for further details.
ComponentDelimiter | The delimiter character to use to separate classes. |
EdifactSyntaxVersion | Changes the syntax version used for EDIFACT control segments. |
EDIStandard | The document format. |
ElementDelimiter | The delimiter character to use to separate data elements. |
Encoding | The character encoding to be applied when reading and writing data. |
IncludeUNA | Whether to include the UNA segment in the output. |
ReleaseChar | The character to use to escape delimiters within values. |
RepetitionChar | The repetition character. |
SegmentDelimiter | The delimiter character to use to separate segments. |
StrictSchemaValidation | Specifies the behavior during schema validation. |
TransactionOnly | Ignores interchange and functional group validation, allowing you to build the transaction body. |
BuildInfo | Information about the product's build. |
CodePage | The system code page used for Unicode to Multibyte translations. |
LicenseInfo | Information about the current license. |
MaskSensitive | Whether sensitive data is masked in log messages. |
ProcessIdleEvents | Whether the class uses its internal event loop to process events when the main thread is idle. |
SelectWaitMillis | The length of time in milliseconds the class will wait when DoEvents is called if there are no events to process. |
UseFIPSCompliantAPI | Tells the class whether or not to use FIPS certified APIs. |
UseInternalSecurityAPI | Whether or not to use the system security libraries or an internal implementation. |
FileWriteMode Property (TRADACOMSWriter Class)
Controls how the output file is opened.
Syntax
ANSI (Cross Platform) int GetFileWriteMode();
int SetFileWriteMode(int iFileWriteMode); Unicode (Windows) INT GetFileWriteMode();
INT SetFileWriteMode(INT iFileWriteMode);
Possible Values
FWM_CREATE(0),
FWM_OVERWRITE(1),
FWM_APPEND(2)
int ipworkseditranslator_tradacomswriter_getfilewritemode(void* lpObj);
int ipworkseditranslator_tradacomswriter_setfilewritemode(void* lpObj, int iFileWriteMode);
int GetFileWriteMode();
int SetFileWriteMode(int iFileWriteMode);
Default Value
0
Remarks
This property controls how the component will open the output file specified in OutputFile. Possible values are:
fwmCreate (0) | Always create a new file. If the file already exists, an error will be raised. |
fwmOverwrite (1) | If the output file already exists, it will be overwritten. |
fwmAppend (2) | If the output file already exists, data will be appended to it. |
Data Type
Integer
OutputData Property (TRADACOMSWriter Class)
Contains the output data.
Syntax
ANSI (Cross Platform) int GetOutputData(char* &lpOutputData, int &lenOutputData); Unicode (Windows) INT GetOutputData(LPSTR &lpOutputData, INT &lenOutputData);
int ipworkseditranslator_tradacomswriter_getoutputdata(void* lpObj, char** lpOutputData, int* lenOutputData);
QByteArray GetOutputData();
Default Value
""
Remarks
This property will be populated with the contents of the EDI data as output by the class when no OutputFile has been specified and SetOutputStream has not been called with a valid output stream.
This property is read-only.
Data Type
Binary String
OutputFile Property (TRADACOMSWriter Class)
Specifies the name of the EDI file to write to.
Syntax
ANSI (Cross Platform) char* GetOutputFile();
int SetOutputFile(const char* lpszOutputFile); Unicode (Windows) LPWSTR GetOutputFile();
INT SetOutputFile(LPCWSTR lpszOutputFile);
char* ipworkseditranslator_tradacomswriter_getoutputfile(void* lpObj);
int ipworkseditranslator_tradacomswriter_setoutputfile(void* lpObj, const char* lpszOutputFile);
QString GetOutputFile();
int SetOutputFile(QString qsOutputFile);
Default Value
""
Remarks
Set OutputFile before calling the StartInterchangeHeader method to write an EDI interchange to a file on disk.
Data Type
String
SchemaFormat Property (TRADACOMSWriter Class)
The format of the schema file.
Syntax
ANSI (Cross Platform) int GetSchemaFormat();
int SetSchemaFormat(int iSchemaFormat); Unicode (Windows) INT GetSchemaFormat();
INT SetSchemaFormat(INT iSchemaFormat);
Possible Values
SCHEMA_AUTOMATIC(0),
SCHEMA_BINARY(1),
SCHEMA_BIZ_TALK(2),
SCHEMA_SEF(3),
SCHEMA_BOTS(4),
SCHEMA_ALTOVA(5),
SCHEMA_JSON(6)
int ipworkseditranslator_tradacomswriter_getschemaformat(void* lpObj);
int ipworkseditranslator_tradacomswriter_setschemaformat(void* lpObj, int iSchemaFormat);
int GetSchemaFormat();
int SetSchemaFormat(int iSchemaFormat);
Default Value
0
Remarks
Set SchemaFormat before calling the LoadSchema method to specify the loading schema format.
The following schema formats are supported:
0 (schemaAutomatic - default) | The schema type is automatically determined based on file extension. |
1 (schemaBinary) | A binary schema that was previously compiled by calling CompileSchema. |
2 (schemaBizTalk) | BizTalk (XSD): http://msdn.microsoft.com/en-us/library/aa559426(v=BTS.70).aspx |
3 (schemaSEF) | TIBCO Standard Exchange Format (SEF): https://docs.tibco.com/products/tibco-foresight-edisim-6-18-0 |
5 (schemaAltova) | Altova: http://www.altova.com/ |
6 (schemaJSON) | JSON |
Data Type
Integer
Suffix Property (TRADACOMSWriter Class)
What to append after each segment delimiter.
Syntax
ANSI (Cross Platform) int GetSuffix();
int SetSuffix(int iSuffix); Unicode (Windows) INT GetSuffix();
INT SetSuffix(INT iSuffix);
Possible Values
SUFFIX_NONE(0),
SUFFIX_CR(1),
SUFFIX_LF(2),
SUFFIX_CRLF(3)
int ipworkseditranslator_tradacomswriter_getsuffix(void* lpObj);
int ipworkseditranslator_tradacomswriter_setsuffix(void* lpObj, int iSuffix);
int GetSuffix();
int SetSuffix(int iSuffix);
Default Value
0
Remarks
If Suffix is different from suffixNone, trailing (suffix) characters are appended after each segment delimiter. This is useful if you want to have a carriage return/line feed after each segment to make the document more readable.
This property is not available at design time.
Data Type
Integer
CompileSchema Method (TRADACOMSWriter Class)
Compiles an existing XSD schema into an optimized binary representation.
Syntax
ANSI (Cross Platform) int CompileSchema(const char* lpszXsdSchema, const char* lpszBinSchema); Unicode (Windows) INT CompileSchema(LPCWSTR lpszXsdSchema, LPCWSTR lpszBinSchema);
int ipworkseditranslator_tradacomswriter_compileschema(void* lpObj, const char* lpszXsdSchema, const char* lpszBinSchema);
int CompileSchema(const QString& qsXsdSchema, const QString& qsBinSchema);
Remarks
This method parses XsdSchema and generates an optimized binary representation that is saved into the path referenced by BinSchema. Binary schemas are smaller and require less resources when loading later using LoadSchema
If the schema file does not exists or cannot be parsed as an EDI schema, the component throws an exception.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
Config Method (TRADACOMSWriter Class)
Sets or retrieves a configuration setting.
Syntax
ANSI (Cross Platform) char* Config(const char* lpszConfigurationString); Unicode (Windows) LPWSTR Config(LPCWSTR lpszConfigurationString);
char* ipworkseditranslator_tradacomswriter_config(void* lpObj, const char* lpszConfigurationString);
QString Config(const QString& qsConfigurationString);
Remarks
Config is a generic method available in every class. It is used to set and retrieve configuration settings for the class.
These settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the class, access to these internal properties is provided through the Config method.
To set a configuration setting named PROPERTY, you must call Config("PROPERTY=VALUE"), where VALUE is the value of the setting expressed as a string. For boolean values, use the strings "True", "False", "0", "1", "Yes", or "No" (case does not matter).
To read (query) the value of a configuration setting, you must call Config("PROPERTY"). The value will be returned as a string.
Error Handling (C++)
This method returns a String value; after it returns, call the GetLastErrorCode() method to obtain its result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message.
CreateFunctionalGroupFooter Method (TRADACOMSWriter Class)
Closes the current functional group by writing its footer segment.
Syntax
Remarks
The CreateFunctionalGroupFooter method will write any existing segments to the output stream and then generate and write the functional group closing segment (GE or UNE). If there is an open transaction set, CreateFunctionalGroupFooter will first call CreateTransactionFooter to close it. If there is no functional group open, an exception will be thrown.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
CreateInterchangeFooter Method (TRADACOMSWriter Class)
Closes the current interchange by writing its footer segment.
Syntax
Remarks
The CreateInterchangeFooter method will write any existing segments to the output stream and then generate and write the interchange closing segment (IEA or UNZ). If there is an open transaction set, CreateInterchangeFooter will first call CreateTransactionFooter to close it. If there is an open functional group, CreateInterchangeFooter will first call CreateFunctionalGroupFooter to close it. If there is no interchange open, an exception will be thrown.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
CreateTransactionFooter Method (TRADACOMSWriter Class)
Closes the current transaction set by writing its footer segment.
Syntax
Remarks
The CreateTransactionFooter method will write any existing segments to the output stream and then generate and write the transaction set closing segment (SE or UNT). If there are no open transaction sets, an exception will be thrown.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
DisplaySchemaInfo Method (TRADACOMSWriter Class)
Returns a string showing the structure of the schema defining the document.
Syntax
ANSI (Cross Platform) char* DisplaySchemaInfo(); Unicode (Windows) LPWSTR DisplaySchemaInfo();
char* ipworkseditranslator_tradacomswriter_displayschemainfo(void* lpObj);
QString DisplaySchemaInfo();
Remarks
After calling LoadSchema this may be called to obtain information about the structure of the schema defining the document. If the desired XPath is not known this helps determine the structure so that the correct XPath can be built.
Note: A valid schema must be loaded via LoadSchema.
For instance:
Console.WriteLine(component.DisplaySchemaInfo());
Will output text like:
UNH[0,1] BGM[0,1] DTM[0,35] PAI[0,1] ALI[0,5] IMD[0,1] FTX[0,10] LOC[0,10] GIS[0,10] DGS[0,1] RFFLoop1[0,99] RFF[0,1] DTM_2[0,5] GIR[0,5] LOC_2[0,2] MEA[0,5] QTY[0,2] FTX_2[0,5] MOA[0,2] NADLoop1[0,99] NAD[0,1] LOC_3[0,25] FII[0,5] RFFLoop2[0,9999] RFF_2[0,1] DTM_3[0,5] DOCLoop1[0,5] DOC[0,1] DTM_4[0,5] CTALoop1[0,5] CTA[0,1] COM[0,5] TAXLoop1[0,5] TAX[0,1] MOA_2[0,1] LOC_4[0,5] CUXLoop1[0,5] CUX[0,1] DTM_5[0,5] PATLoop1[0,10] PAT[0,1] DTM_6[0,5] PCD[0,1] MOA_3[0,1] PAI_2[0,1] FII_2[0,1] TDTLoop1[0,10] TDT[0,1] TSR[0,1] LOCLoop1[0,10] LOC_5[0,1] DTM_7[0,5] RFFLoop3[0,9999] RFF_3[0,1] DTM_8[0,5] TODLoop1[0,5] TOD[0,1] LOC_6[0,2] PACLoop1[0,1000] PAC[0,1] MEA_2[0,5] EQD[0,1] PCILoop1[0,5] PCI[0,1] RFF_4[0,1] DTM_9[0,5] GIN[0,5] ALCLoop1[0,9999] ALC[0,1] ALI_2[0,5] FTX_3[0,1] RFFLoop4[0,5] RFF_5[0,1] DTM_10[0,5] QTYLoop1[0,1] QTY_2[0,1] RNG[0,1] PCDLoop1[0,1] PCD_2[0,1] RNG_2[0,1] MOALoop1[0,2] MOA_4[0,1] RNG_3[0,1] CUX_2[0,1] DTM_11[0,1] RTELoop1[0,1] RTE[0,1] RNG_4[0,1] TAXLoop2[0,5] TAX_2[0,1] MOA_5[0,1] RCSLoop1[0,100] RCS[0,1] RFF_6[0,5] DTM_12[0,5] FTX_4[0,5] AJTLoop1[0,1] AJT[0,1] FTX_5[0,5] INPLoop1[0,1] INP[0,1] FTX_6[0,5] LINLoop1[0,9999999] LIN[0,1] PIA[0,25] IMD_2[0,10] MEA_3[0,5] QTY_3[0,5] PCD_3[0,1] ALI_3[0,5] DTM_13[0,35] GIN_2[0,1000] GIR_2[0,1000] QVR[0,1] EQD_2[0,1] FTX_7[0,5] DGS_2[0,1] MOALoop2[0,10] MOA_6[0,1] CUX_3[0,1] PATLoop2[0,10] PAT_2[0,1] DTM_14[0,5] PCD_4[0,1] MOA_7[0,1] PRILoop1[0,25] PRI[0,1] CUX_4[0,1] APR[0,1] RNG_5[0,1] DTM_15[0,5] RFFLoop5[0,10] RFF_7[0,1] DTM_16[0,5] PACLoop2[0,10] PAC_2[0,1] MEA_4[0,10] EQD_3[0,1] PCILoop2[0,10] PCI_2[0,1] RFF_8[0,1] DTM_17[0,5] GIN_3[0,10] LOCLoop2[0,9999] LOC_7[0,1] QTY_4[0,100] DTM_18[0,5] TAXLoop3[0,99] TAX_3[0,1] MOA_8[0,1] LOC_8[0,5] NADLoop2[0,99] NAD_2[0,1] LOC_9[0,5] RFFLoop6[0,5] RFF_9[0,1] DTM_19[0,5] DOCLoop2[0,5] DOC_2[0,1] DTM_20[0,5] CTALoop2[0,5] CTA_2[0,1] COM_2[0,5] ALCLoop2[0,30] ALC_2[0,1] ALI_4[0,5] DTM_21[0,5] FTX_8[0,1] QTYLoop2[0,1] QTY_5[0,1] RNG_6[0,1] PCDLoop2[0,1] PCD_5[0,1] RNG_7[0,1] MOALoop3[0,2] MOA_9[0,1] RNG_8[0,1] CUX_5[0,1] DTM_22[0,1] RTELoop2[0,1] RTE_2[0,1] RNG_9[0,1] TAXLoop4[0,5] TAX_4[0,1] MOA_10[0,1] TDTLoop2[0,10] TDT_2[0,1] LOCLoop3[0,10] LOC_10[0,1] DTM_23[0,5] TODLoop2[0,5] TOD_2[0,1] LOC_11[0,2] RCSLoop2[0,100] RCS_2[0,1] RFF_10[0,5] DTM_24[0,5] FTX_9[0,5] GISLoop1[0,10] GIS_2[0,1] RFF_11[0,1] DTM_25[0,5] GIR_3[0,5] LOC_12[0,2] MEA_5[0,5] QTY_6[0,2] FTX_10[0,5] MOA_11[0,2] UNS[0,1] CNT[0,10] MOALoop4[0,100] MOA_12[0,1] RFFLoop7[0,1] RFF_12[0,1] DTM_26[0,5] TAXLoop5[0,10] TAX_5[0,1] MOA_13[0,2] ALCLoop3[0,15] ALC_3[0,1] ALI_5[0,1] MOA_14[0,2] FTX_11[0,1] UNT[0,1]
Error Handling (C++)
This method returns a String value; after it returns, call the GetLastErrorCode() method to obtain its result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message.
EndElement Method (TRADACOMSWriter Class)
Finishes the current composite data element.
Syntax
ANSI (Cross Platform) int EndElement(); Unicode (Windows) INT EndElement();
int ipworkseditranslator_tradacomswriter_endelement(void* lpObj);
int EndElement();
Remarks
Call EndElement once you've written all components in an element started with StartElement. You should not call this if you wrote a simple element using WriteElementString
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
EndSegment Method (TRADACOMSWriter Class)
Ends writing the current segment.
Syntax
ANSI (Cross Platform) int EndSegment(); Unicode (Windows) INT EndSegment();
int ipworkseditranslator_tradacomswriter_endsegment(void* lpObj);
int EndSegment();
Remarks
EndSegment terminates writing the current segment and flushes it to the output stream/file.
You should call EndSegment to close a segment started with StartSegment, StartInterchangeHeader, StartFunctionalGroupHeader or StartTransactionHeader.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
Flush Method (TRADACOMSWriter Class)
Forces any pending segments to be written to the output stream without closing it.
Syntax
ANSI (Cross Platform) int Flush(); Unicode (Windows) INT Flush();
int ipworkseditranslator_tradacomswriter_flush(void* lpObj);
int Flush();
Remarks
The Flush method forces the component to write the last created segment to the output stream and then flush the output stream.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
LoadSchema Method (TRADACOMSWriter Class)
Loads a schema file describing a Transaction Set.
Syntax
ANSI (Cross Platform) int LoadSchema(const char* lpszFileName); Unicode (Windows) INT LoadSchema(LPCWSTR lpszFileName);
int ipworkseditranslator_tradacomswriter_loadschema(void* lpObj, const char* lpszFileName);
int LoadSchema(const QString& qsFileName);
Remarks
This method parses the File and loads it into an internal schema list. The class will attempt to automatically detect the SchemaFormat.
If the schema file does not exist or cannot be parsed as an EDI schema, the class fails with an error.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
RepeatElement Method (TRADACOMSWriter Class)
Adds a new repetition to the current element.
Syntax
ANSI (Cross Platform) int RepeatElement(); Unicode (Windows) INT RepeatElement();
int ipworkseditranslator_tradacomswriter_repeatelement(void* lpObj);
int RepeatElement();
Remarks
RepeatElement is used to write repeated data elements in supporting version of X12 or EDIFACT. To use it, first write the first repetition of the simple or composite data element and then call RepeatElement to repeat it, then write again.
Example: Repeating a simple data element:
EDIWriter writer = new EDIWriter();
...
writer.StartSegment("Tag");
...
writer.WriteElementString("R1_1");
writer.RepeatElement();
writer.WriteElementString("R1_2");
writer.RepeatElement();
writer.WriteElementString("R1_3");
...
writer.EndSegment();
Example: Repeating a composite data element:
EDIWriter writer = new EDIWriter();
...
writer.StartSegment("Tag");
...
writer.StartElement();
writer.WriteComponentString("C1_1");
writer.WriteComponentString("C2_1");
writer.RepeatElement();
writer.WriteComponentString("C1_2");
writer.WriteComponentString("C2_2");
writer.RepeatElement();
writer.WriteComponentString("C1_3");
writer.EndElement();
...
writer.EndSegment();
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
Reset Method (TRADACOMSWriter Class)
Resets the state of the control.
Syntax
ANSI (Cross Platform) int Reset(); Unicode (Windows) INT Reset();
int ipworkseditranslator_tradacomswriter_reset(void* lpObj);
int Reset();
Remarks
Resets the state of the writer. If a document has been partially written already, it will not be closed correctly and the write process will be aborted.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
SkipComponent Method (TRADACOMSWriter Class)
Moves to the next sub-element in the current composite element in the current segment.
Syntax
ANSI (Cross Platform) int SkipComponent(); Unicode (Windows) INT SkipComponent();
int ipworkseditranslator_tradacomswriter_skipcomponent(void* lpObj);
int SkipComponent();
Remarks
SkipComponent can be used to avoid providing a value for the current sub-element in the opened composite element within the current segment.
If the sub-element already has a value (such as one provided by default by the class), said value will not be overwritten.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
SkipElement Method (TRADACOMSWriter Class)
Moves to the next data element in the current segment.
Syntax
ANSI (Cross Platform) int SkipElement(); Unicode (Windows) INT SkipElement();
int ipworkseditranslator_tradacomswriter_skipelement(void* lpObj);
int SkipElement();
Remarks
SkipElement can be used to avoid providing a value for the current element in the current segment.
If the element already has a value (such as one provided by default by the class), said value will not be overwritten.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
StartElement Method (TRADACOMSWriter Class)
Starts a new EDI composite data element on the current segment.
Syntax
ANSI (Cross Platform) int StartElement(); Unicode (Windows) INT StartElement();
int ipworkseditranslator_tradacomswriter_startelement(void* lpObj);
int StartElement();
Remarks
When called, a new composite data element is created in the current segment. You can then call WriteComponentString one or more times to write the individual components or subelements that make up this composite.
Call EndElement once you've written all components in this element.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
StartFunctionalGroupHeader Method (TRADACOMSWriter Class)
Creates a new EDI functional group header segment on the current document.
Syntax
ANSI (Cross Platform) int StartFunctionalGroupHeader(); Unicode (Windows) INT StartFunctionalGroupHeader();
int ipworkseditranslator_tradacomswriter_startfunctionalgroupheader(void* lpObj);
int StartFunctionalGroupHeader();
Remarks
When called, a new functional group start (GS or UNG) segment is created and set as the current segment. You should then set the values on said segment before adding a new transaction set within the document.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
StartInterchangeHeader Method (TRADACOMSWriter Class)
Creates a new EDI Interchange header segment on the current document.
Syntax
ANSI (Cross Platform) int StartInterchangeHeader(const char* lpszVersion); Unicode (Windows) INT StartInterchangeHeader(LPCWSTR lpszVersion);
int ipworkseditranslator_tradacomswriter_startinterchangeheader(void* lpObj, const char* lpszVersion);
int StartInterchangeHeader(const QString& qsVersion);
Remarks
When called, a new interchange start (ISA or UNB) segment is created and set as the current segment. You should then set the values on said segment before creating a functional group or a new transaction set within the document.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
StartSegment Method (TRADACOMSWriter Class)
Creates a new EDI data segment on the current document.
Syntax
ANSI (Cross Platform) int StartSegment(const char* lpszSegmentType); Unicode (Windows) INT StartSegment(LPCWSTR lpszSegmentType);
int ipworkseditranslator_tradacomswriter_startsegment(void* lpObj, const char* lpszSegmentType);
int StartSegment(const QString& qsSegmentType);
Remarks
When called, a new data segment is created in the current transaction and set as the current segment. You can then set the values on said segment. Creating a new data segment automatically writes the previous current segment to the output stream.
The SegmentType argument specifies the type of data segment to create, using an XPath-like syntax, based on the transaction set schema. For example, to create a new N1 segment on the first N1 loop, specify "/N1Loop1/N1".
It's important to realize that segments must be created in the same order they should appear on the target EDI document. The EDIWriter component doesn't automatically enforce ordering rules, nor does it force the document to reorder segments in loops automatically.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
StartTransactionHeader Method (TRADACOMSWriter Class)
Creates a new EDI transaction set header on the current document.
Syntax
ANSI (Cross Platform) int StartTransactionHeader(const char* lpszCode); Unicode (Windows) INT StartTransactionHeader(LPCWSTR lpszCode);
int ipworkseditranslator_tradacomswriter_starttransactionheader(void* lpObj, const char* lpszCode);
int StartTransactionHeader(const QString& qsCode);
Remarks
When called, a new transaction set start (ST or UNH) segment is created and set as the current segment. You should then set the values on said segment before adding creating transaction data segments.
The Code argument should specify the transaction code you want to create (for example, "850" or "INVOIC"). This value, together with the EDI specification and the version provided in the StartInterchangeHeader method are used to locate a matching transaction set schema on the components schema cache. You must make sure that a corresponding schema has been successfully loaded into the component by using the LoadSchema method before trying to call StartTransactionHeader.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
WriteComponentString Method (TRADACOMSWriter Class)
Sets the value of the next class within the current element in the current segment.
Syntax
ANSI (Cross Platform) int WriteComponentString(const char* lpszValue); Unicode (Windows) INT WriteComponentString(LPCWSTR lpszValue);
int ipworkseditranslator_tradacomswriter_writecomponentstring(void* lpObj, const char* lpszValue);
int WriteComponentString(const QString& qsValue);
Remarks
Use the WriteComponentString method to specify a value for an individual component within a composite data element.
To write an entire composite data element, first call the StartElement method, then do one or more calls to WriteComponentString. Finish the composite element by calling the EndElement method.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
WriteElementString Method (TRADACOMSWriter Class)
Sets a value of the next element in the current segment to a simple value.
Syntax
ANSI (Cross Platform) int WriteElementString(const char* lpszValue); Unicode (Windows) INT WriteElementString(LPCWSTR lpszValue);
int ipworkseditranslator_tradacomswriter_writeelementstring(void* lpObj, const char* lpszValue);
int WriteElementString(const QString& qsValue);
Remarks
Use the WriteElementString method to specify a value for the next data element with simple content on the current segment.
To write a composite data element, even if it has a single sub-element, use the StartElement and WriteComponentString methods instead.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
WriteTransaction Method (TRADACOMSWriter Class)
Writes an entire transaction to the output.
Syntax
ANSI (Cross Platform) int WriteTransaction(const char* lpszValue); Unicode (Windows) INT WriteTransaction(LPCWSTR lpszValue);
int ipworkseditranslator_tradacomswriter_writetransaction(void* lpObj, const char* lpszValue);
int WriteTransaction(const QString& qsValue);
Remarks
Use the WriteTransaction method when you have generated a complete transaction outside of the class and want to include it in the document being created by this instance.
No validation is done on the contents of the Value parameter. You must ensure the transaction data is valid and matches the same conventions (delimiters, etc) being used in this document.
Error Handling (C++)
This method returns a result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. If an error occurs, the GetLastError() method can be called to retrieve the associated error message. (Note: This method's result code can also be obtained by calling the GetLastErrorCode() method after it returns.)
Error Event (TRADACOMSWriter Class)
Fired when information is available about errors during data delivery.
Syntax
ANSI (Cross Platform) virtual int FireError(TRADACOMSWriterErrorEventParams *e);
typedef struct {
int ErrorCode;
const char *Description; int reserved; } TRADACOMSWriterErrorEventParams;
Unicode (Windows) virtual INT FireError(TRADACOMSWriterErrorEventParams *e);
typedef struct {
INT ErrorCode;
LPCWSTR Description; INT reserved; } TRADACOMSWriterErrorEventParams;
#define EID_TRADACOMSWRITER_ERROR 1 virtual INT IPWORKSEDITRANSLATOR_CALL FireError(INT &iErrorCode, LPSTR &lpszDescription);
class TRADACOMSWriterErrorEventParams { public: int ErrorCode(); const QString &Description(); int EventRetVal(); void SetEventRetVal(int iRetVal); };
// To handle, connect one or more slots to this signal. void Error(TRADACOMSWriterErrorEventParams *e);
// Or, subclass TRADACOMSWriter and override this emitter function. virtual int FireError(TRADACOMSWriterErrorEventParams *e) {...}
Remarks
The Error event is fired in case of exceptional conditions during message processing. Normally the class fails with an error.
The ErrorCode parameter contains an error code, and the Description parameter contains a textual description of the error. For a list of valid error codes and their descriptions, please refer to the Error Codes section.
Output Event (TRADACOMSWriter Class)
Fires whenever a segment is complete.
Syntax
ANSI (Cross Platform) virtual int FireOutput(TRADACOMSWriterOutputEventParams *e);
typedef struct {
const char *OutputData; int lenOutputData; int reserved; } TRADACOMSWriterOutputEventParams;
Unicode (Windows) virtual INT FireOutput(TRADACOMSWriterOutputEventParams *e);
typedef struct {
LPCSTR OutputData; INT lenOutputData; INT reserved; } TRADACOMSWriterOutputEventParams;
#define EID_TRADACOMSWRITER_OUTPUT 2 virtual INT IPWORKSEDITRANSLATOR_CALL FireOutput(LPSTR &lpOutputData, INT &lenOutputData);
class TRADACOMSWriterOutputEventParams { public: const QByteArray &OutputData(); int EventRetVal(); void SetEventRetVal(int iRetVal); };
// To handle, connect one or more slots to this signal. void Output(TRADACOMSWriterOutputEventParams *e);
// Or, subclass TRADACOMSWriter and override this emitter function. virtual int FireOutput(TRADACOMSWriterOutputEventParams *e) {...}
Remarks
The Output event will fire when the writer completes a new segment and writes data to the output stream or buffer. The Data parameter contains the data bytes.
Warning Event (TRADACOMSWriter Class)
Fires whenever a validation warning is encountered.
Syntax
ANSI (Cross Platform) virtual int FireWarning(TRADACOMSWriterWarningEventParams *e);
typedef struct {
int WarnCode;
const char *Message;
int SegmentNumber;
const char *SegmentTag;
const char *SegmentErrorCode;
const char *ElementErrorCode;
int ElementPosition; int reserved; } TRADACOMSWriterWarningEventParams;
Unicode (Windows) virtual INT FireWarning(TRADACOMSWriterWarningEventParams *e);
typedef struct {
INT WarnCode;
LPCWSTR Message;
INT SegmentNumber;
LPCWSTR SegmentTag;
LPCWSTR SegmentErrorCode;
LPCWSTR ElementErrorCode;
INT ElementPosition; INT reserved; } TRADACOMSWriterWarningEventParams;
#define EID_TRADACOMSWRITER_WARNING 3 virtual INT IPWORKSEDITRANSLATOR_CALL FireWarning(INT &iWarnCode, LPSTR &lpszMessage, INT &iSegmentNumber, LPSTR &lpszSegmentTag, LPSTR &lpszSegmentErrorCode, LPSTR &lpszElementErrorCode, INT &iElementPosition);
class TRADACOMSWriterWarningEventParams { public: int WarnCode(); const QString &Message(); int SegmentNumber(); const QString &SegmentTag(); const QString &SegmentErrorCode(); const QString &ElementErrorCode(); int ElementPosition(); int EventRetVal(); void SetEventRetVal(int iRetVal); };
// To handle, connect one or more slots to this signal. void Warning(TRADACOMSWriterWarningEventParams *e);
// Or, subclass TRADACOMSWriter and override this emitter function. virtual int FireWarning(TRADACOMSWriterWarningEventParams *e) {...}
Remarks
The Warning event will fire if a validation error is encountered when writing a new segment to the output document. The WarnCode parameter contains the type of warning encountered. Message is a textual description of the problem. SegmentNumber is the index of the segment where the problem was found.
0 | The component is not required but is present. |
1 | Invalid segment count. |
2 | Invalid transaction count. |
3 | Invalid group count. |
4 | Invalid interchange control number. |
5 | Invalid group control number. |
6 | Invalid transaction control number. |
10 | A required data element is missing. |
11 | Invalid field length. |
12 | Invalid field value. |
13 | A required component is missing. |
14 | The data element is not defined but is present. |
30 | Required segment is missing. |
31 | Required loop is missing. |
32 | Occurrences exceeds the schema defined limit. |
33 | Occurrences is less than the schema defined minimum. |
40 | Paired rule validation failed, the pair of elements must be present. |
41 | At least one of element is required, see message for list of elements. |
42 | Exclusion validation failed, only one of the elements can be present. |
43 | Conditional rule validation failed. |
44 | List conditional rule validation failed. |
45 | First then none validation failed. The presence of an element requires that other specific elements must not be present. |
46 | Only one or none of the elements can be present. |
Config Settings (TRADACOMSWriter Class)
The class accepts one or more of the following configuration settings. Configuration settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the class, access to these internal properties is provided through the Config method.TRADACOMSWriter Config Settings
- 1 (EDIFACT - default)
- 3 (TRADACOMS)
Base Config Settings
The following is a list of valid code page identifiers:
Identifier | Name |
037 | IBM EBCDIC - U.S./Canada |
437 | OEM - United States |
500 | IBM EBCDIC - International |
708 | Arabic - ASMO 708 |
709 | Arabic - ASMO 449+, BCON V4 |
710 | Arabic - Transparent Arabic |
720 | Arabic - Transparent ASMO |
737 | OEM - Greek (formerly 437G) |
775 | OEM - Baltic |
850 | OEM - Multilingual Latin I |
852 | OEM - Latin II |
855 | OEM - Cyrillic (primarily Russian) |
857 | OEM - Turkish |
858 | OEM - Multilingual Latin I + Euro symbol |
860 | OEM - Portuguese |
861 | OEM - Icelandic |
862 | OEM - Hebrew |
863 | OEM - Canadian-French |
864 | OEM - Arabic |
865 | OEM - Nordic |
866 | OEM - Russian |
869 | OEM - Modern Greek |
870 | IBM EBCDIC - Multilingual/ROECE (Latin-2) |
874 | ANSI/OEM - Thai (same as 28605, ISO 8859-15) |
875 | IBM EBCDIC - Modern Greek |
932 | ANSI/OEM - Japanese, Shift-JIS |
936 | ANSI/OEM - Simplified Chinese (PRC, Singapore) |
949 | ANSI/OEM - Korean (Unified Hangul Code) |
950 | ANSI/OEM - Traditional Chinese (Taiwan; Hong Kong SAR, PRC) |
1026 | IBM EBCDIC - Turkish (Latin-5) |
1047 | IBM EBCDIC - Latin 1/Open System |
1140 | IBM EBCDIC - U.S./Canada (037 + Euro symbol) |
1141 | IBM EBCDIC - Germany (20273 + Euro symbol) |
1142 | IBM EBCDIC - Denmark/Norway (20277 + Euro symbol) |
1143 | IBM EBCDIC - Finland/Sweden (20278 + Euro symbol) |
1144 | IBM EBCDIC - Italy (20280 + Euro symbol) |
1145 | IBM EBCDIC - Latin America/Spain (20284 + Euro symbol) |
1146 | IBM EBCDIC - United Kingdom (20285 + Euro symbol) |
1147 | IBM EBCDIC - France (20297 + Euro symbol) |
1148 | IBM EBCDIC - International (500 + Euro symbol) |
1149 | IBM EBCDIC - Icelandic (20871 + Euro symbol) |
1200 | Unicode UCS-2 Little-Endian (BMP of ISO 10646) |
1201 | Unicode UCS-2 Big-Endian |
1250 | ANSI - Central European |
1251 | ANSI - Cyrillic |
1252 | ANSI - Latin I |
1253 | ANSI - Greek |
1254 | ANSI - Turkish |
1255 | ANSI - Hebrew |
1256 | ANSI - Arabic |
1257 | ANSI - Baltic |
1258 | ANSI/OEM - Vietnamese |
1361 | Korean (Johab) |
10000 | MAC - Roman |
10001 | MAC - Japanese |
10002 | MAC - Traditional Chinese (Big5) |
10003 | MAC - Korean |
10004 | MAC - Arabic |
10005 | MAC - Hebrew |
10006 | MAC - Greek I |
10007 | MAC - Cyrillic |
10008 | MAC - Simplified Chinese (GB 2312) |
10010 | MAC - Romania |
10017 | MAC - Ukraine |
10021 | MAC - Thai |
10029 | MAC - Latin II |
10079 | MAC - Icelandic |
10081 | MAC - Turkish |
10082 | MAC - Croatia |
12000 | Unicode UCS-4 Little-Endian |
12001 | Unicode UCS-4 Big-Endian |
20000 | CNS - Taiwan |
20001 | TCA - Taiwan |
20002 | Eten - Taiwan |
20003 | IBM5550 - Taiwan |
20004 | TeleText - Taiwan |
20005 | Wang - Taiwan |
20105 | IA5 IRV International Alphabet No. 5 (7-bit) |
20106 | IA5 German (7-bit) |
20107 | IA5 Swedish (7-bit) |
20108 | IA5 Norwegian (7-bit) |
20127 | US-ASCII (7-bit) |
20261 | T.61 |
20269 | ISO 6937 Non-Spacing Accent |
20273 | IBM EBCDIC - Germany |
20277 | IBM EBCDIC - Denmark/Norway |
20278 | IBM EBCDIC - Finland/Sweden |
20280 | IBM EBCDIC - Italy |
20284 | IBM EBCDIC - Latin America/Spain |
20285 | IBM EBCDIC - United Kingdom |
20290 | IBM EBCDIC - Japanese Katakana Extended |
20297 | IBM EBCDIC - France |
20420 | IBM EBCDIC - Arabic |
20423 | IBM EBCDIC - Greek |
20424 | IBM EBCDIC - Hebrew |
20833 | IBM EBCDIC - Korean Extended |
20838 | IBM EBCDIC - Thai |
20866 | Russian - KOI8-R |
20871 | IBM EBCDIC - Icelandic |
20880 | IBM EBCDIC - Cyrillic (Russian) |
20905 | IBM EBCDIC - Turkish |
20924 | IBM EBCDIC - Latin-1/Open System (1047 + Euro symbol) |
20932 | JIS X 0208-1990 & 0121-1990 |
20936 | Simplified Chinese (GB2312) |
21025 | IBM EBCDIC - Cyrillic (Serbian, Bulgarian) |
21027 | Extended Alpha Lowercase |
21866 | Ukrainian (KOI8-U) |
28591 | ISO 8859-1 Latin I |
28592 | ISO 8859-2 Central Europe |
28593 | ISO 8859-3 Latin 3 |
28594 | ISO 8859-4 Baltic |
28595 | ISO 8859-5 Cyrillic |
28596 | ISO 8859-6 Arabic |
28597 | ISO 8859-7 Greek |
28598 | ISO 8859-8 Hebrew |
28599 | ISO 8859-9 Latin 5 |
28605 | ISO 8859-15 Latin 9 |
29001 | Europa 3 |
38598 | ISO 8859-8 Hebrew |
50220 | ISO 2022 Japanese with no halfwidth Katakana |
50221 | ISO 2022 Japanese with halfwidth Katakana |
50222 | ISO 2022 Japanese JIS X 0201-1989 |
50225 | ISO 2022 Korean |
50227 | ISO 2022 Simplified Chinese |
50229 | ISO 2022 Traditional Chinese |
50930 | Japanese (Katakana) Extended |
50931 | US/Canada and Japanese |
50933 | Korean Extended and Korean |
50935 | Simplified Chinese Extended and Simplified Chinese |
50936 | Simplified Chinese |
50937 | US/Canada and Traditional Chinese |
50939 | Japanese (Latin) Extended and Japanese |
51932 | EUC - Japanese |
51936 | EUC - Simplified Chinese |
51949 | EUC - Korean |
51950 | EUC - Traditional Chinese |
52936 | HZ-GB2312 Simplified Chinese |
54936 | Windows XP: GB18030 Simplified Chinese (4 Byte) |
57002 | ISCII Devanagari |
57003 | ISCII Bengali |
57004 | ISCII Tamil |
57005 | ISCII Telugu |
57006 | ISCII Assamese |
57007 | ISCII Oriya |
57008 | ISCII Kannada |
57009 | ISCII Malayalam |
57010 | ISCII Gujarati |
57011 | ISCII Punjabi |
65000 | Unicode UTF-7 |
65001 | Unicode UTF-8 |
Identifier | Name |
1 | ASCII |
2 | NEXTSTEP |
3 | JapaneseEUC |
4 | UTF8 |
5 | ISOLatin1 |
6 | Symbol |
7 | NonLossyASCII |
8 | ShiftJIS |
9 | ISOLatin2 |
10 | Unicode |
11 | WindowsCP1251 |
12 | WindowsCP1252 |
13 | WindowsCP1253 |
14 | WindowsCP1254 |
15 | WindowsCP1250 |
21 | ISO2022JP |
30 | MacOSRoman |
10 | UTF16String |
0x90000100 | UTF16BigEndian |
0x94000100 | UTF16LittleEndian |
0x8c000100 | UTF32String |
0x98000100 | UTF32BigEndian |
0x9c000100 | UTF32LittleEndian |
65536 | Proprietary |
- Product: The product the license is for.
- Product Key: The key the license was generated from.
- License Source: Where the license was found (e.g., RuntimeLicense, License File).
- License Type: The type of license installed (e.g., Royalty Free, Single Server).
- Last Valid Build: The last valid build number for which the license will work.
This setting only works on these classes: AS3Receiver, AS3Sender, Atom, Client(3DS), FTP, FTPServer, IMAP, OFTPClient, SSHClient, SCP, Server(3DS), Sexec, SFTP, SFTPServer, SSHServer, TCPClient, TCPServer.
FIPS mode can be enabled by setting the UseFIPSCompliantAPI configuration setting to true. This is a static setting which applies to all instances of all classes of the toolkit within the process. It is recommended to enable or disable this setting once before the component has been used to establish a connection. Enabling FIPS while an instance of the component is active and connected may result in unexpected behavior.
For more details please see the FIPS 140-2 Compliance article.
Note: This setting is only applicable on Windows.
Note: Enabling FIPS-compliance requires a special license; please contact sales@nsoftware.com for details.
Setting this configuration setting to true tells the class to use the internal implementation instead of using the system security libraries.
On Windows, this setting is set to false by default. On Linux/macOS, this setting is set to true by default.
To use the system security libraries for Linux, OpenSSL support must be enabled. For more information on how to enable OpenSSL, please refer to the OpenSSL Notes section.
Trappable Errors (TRADACOMSWriter Class)
Error Handling (C++)
Call the GetLastErrorCode() method to obtain the last called method's result code; 0 indicates success, while a non-zero error code indicates that this method encountered an error during its execution. Known error codes are listed below. If an error occurs, the GetLastError() method can be called to retrieve the associated error message.
TRADACOMSWriter Errors
1000 Input/Output error | |
1001 No stream or file name were specified for the component | |
1002 Unexpected end of file (EOF). | |
1003 Segment not found. | |
1004 Segment not found in schema. | |
1005 Schema not found. | |
1010 Invalid Writer state. | |
1011 Segment does not have the specified element or component. | |
1044 Error while reading schema file. | |
1099 Unexpected error. |