Connection Type
A currently connected client.
Remarks
This type describes the connection of a client which is currently connected to the component. You may use the different fields of this type to manage the connection.
Fields
AcceptData boolean |
Setting this field to False, temporarily disables data reception (and the DataIn event) on the connection. Setting this to True, re-enables data reception. |
BytesSent int |
This field shows how many bytes were sent after the last assignment to DataToSend. Please check DataToSend for more information. |
Connected boolean |
This field is used to disconnect individual connections and/or show their status. The Connected field may be set to false to close the connection. Connected also shows the status of a particular connection (connected/disconnected). How and when the connection is closed is controlled by the Linger property. Please refer to its description for more information. |
ConnectionId String |
This field contains an identifier generated by the component to identify each connection. This identifier is unique to this connection. |
DataToSend String |
This field contains a string of data to be sent to the remote host. Write-only property. Assigning a string to the DataToSend makes the component send the string to the remote host. The Send method provides similar functionality. When Timeout is set to 0 the component will behave asynchronously. If you are sending data to the remote host faster than it can process it, or faster than the network's bandwidth allows, the outgoing queue might fill up. When this happens, DataToSend fails with exception 10035: "[10035] Operation would block" (WSAEWOULDBLOCK). You can check this error, and then try to send the data again. The BytesSent property shows how many bytes were sent (if any). If 0 bytes were sent, then you can wait for the ReadyToSend event before attempting to send data again. (However, please note that ReadyToSend is not fired when part of the data is successfully sent). |
DataToSendB byte [] |
This field contains a string of data to be sent to the remote host. Write-only property. Assigning a string to the DataToSend makes the component send the string to the remote host. The Send method provides similar functionality. When Timeout is set to 0 the component will behave asynchronously. If you are sending data to the remote host faster than it can process it, or faster than the network's bandwidth allows, the outgoing queue might fill up. When this happens, DataToSend fails with exception 10035: "[10035] Operation would block" (WSAEWOULDBLOCK). You can check this error, and then try to send the data again. The BytesSent property shows how many bytes were sent (if any). If 0 bytes were sent, then you can wait for the ReadyToSend event before attempting to send data again. (However, please note that ReadyToSend is not fired when part of the data is successfully sent). |
EOL String |
The EOL field is used to define boundaries in the input stream using the value of the field. The EOL field is especially useful with ASCII files. Setting it to CRLF ("\r\ n") enables splitting of the incoming ASCII text stream into lines. In this case, one event is fired for each line received (as well as in packet boundaries). The CRLF ("\r\ n") . bytes are discarded. The EOL field is a binary string. In particular, this means that it can be more than one byte long, and it can contain NULL bytes. |
EOLB byte [] |
The EOL field is used to define boundaries in the input stream using the value of the field. The EOL field is especially useful with ASCII files. Setting it to CRLF ("\r\ n") enables splitting of the incoming ASCII text stream into lines. In this case, one event is fired for each line received (as well as in packet boundaries). The CRLF ("\r\ n") . bytes are discarded. The EOL field is a binary string. In particular, this means that it can be more than one byte long, and it can contain NULL bytes. |
LocalAddress String |
This field shows the IP address of the interface through which the connection is passing. LocalAddress is important for multi-homed hosts where it can be used to find which particular network interface an individual connection is going through. |
MaxLineLength int |
This field is the size of an internal buffer which holds received data while waiting for an EOL string. If an EOL string is found in the input stream before MaxLineLength bytes are received, the DataIn event is fired with the EOL parameter set to True, and the buffer is reset. If no EOL is found, and MaxLineLength bytes are accumulated in the buffer, the DataIn event is fired with the EOL parameter set to False, and the buffer is reset. The minimum value for MaxLineLength is 256 bytes. The default value is 2048 bytes. The maximum value is 65536 bytes. |
RemoteHost String |
This field shows the IP address of the remote host through which the connection is coming. The connection must be valid or an error will be fired. If the component is configured to use a SOCKS firewall, the value assigned to this property may be preceded with an "*". If this is the case, the host name is passed to the firewall unresolved and the firewall performs the DNS resolution. |
RemotePort int |
This field shows the TCP port on the remote host through which the connection is coming. The connection must be valid or an error will be fired. |
SingleLineMode boolean |
This field shows the special mode for line-oriented protocols. When SingleLineMode is True, the component treats the incoming data stream as lines separated by CRLF, CR, or LF. The EOL property is ignored. |
Timeout int |
This field contains a timeout for the component. If the Timeout property is set to 0, all operations return immediately, potentially failing with a 'WOULDBLOCK' error if data can't be sent or received immediately. If Timeout is set to a positive value, the component will automatically retry each operation that would otherwise result in a 'WOULDBLOCK' error for a maximum of Timeout seconds. The component will use DoEvents to enter an efficient wait loop during any potential waiting period, making sure that all system events are processed immediately as they arrive. This ensures that the host application does not "freeze" and remains responsive. If Timeout expires, and the operation is not yet complete, the component throws an exception. Please note that by default, all timeouts are inactivity timeouts, i.e. the timeout period is extended by Timeout seconds when any amount of data is successfully sent or received. Optionally, the behavior of the component may be changed to absolute timeouts, i.e. the component will wait for a maximum of Timeout seconds since the beginning of the operation, without extending the timeout period during communications. This behavior is controlled by the AbsoluteTimeout configuration setting. The default value for the Timeout property is 0 (asynchronous operation). |
UploadStream java.io.InputStream |
Setting this field uploads the data in the specified stream to the current connection. The component will automatically close this stream if CloseStreamAfterTransfer is true (default). |
Constructors
public Connection();