TraceRoute Control

Properties   Methods   Events   Config Settings   Errors  

The TraceRoute control allows you to trace the path that the IP packets take on the Internet.

Syntax

TraceRoute

Remarks

The component implements a standard IP TraceRoute as defined in RFC 1393.

To use the control, simply call the TraceTo method and set the Host parameter to the domain name or IP address of the host you want to trace the path to. This is identical to setting the RemoteHost property to the domain name or IP address. The control will start sending probe packets toward the host, and as it receives replies, it will fire Hop events giving information about the route. The same information is also provided in the Hops properties.

The ResolveNames property enables or disables DNS resolution of IP addresses received during the trace. If set to False, only IP addresses are provided. If set to True, the control will attempt to resolve the names of the hosts in the route. This may considerably increase the time it takes to complete the trace.

The HopTimeout property determines the maximum waiting time for a response in each hop of the trace, while the Timeout property defines the maximum waiting time for the whole trace. The HopLimit property specifies the maximum number of hops allowed for a trace.

Property List


The following is the full list of the properties of the control with short descriptions. Click on the links for further details.

HopLimitThis property includes the maximum number of hops to allow for a trace.
HopCountThe number of records in the Hop arrays.
HopErrorCodeThis property contains the error code for a particular hop in the trace.
HopErrorDescriptionThis property contains the error description for a particular hop in the trace.
HopHostAddressThis property contains the IP address of the host for a particular hop in the trace.
HopHostNameThis property contains the name of the host for a particular hop in the trace.
HopTimeThis property contains the amount of time taken by a particular hop in the trace.
HopTimeoutThis property includes the maximum amount of time to wait for an individual hop to complete.
IdleThe current status of the control.
LocalHostThe name of the local host or user-assigned IP interface through which connections are initiated or accepted.
RemoteHostThis property includes the address of a host to trace to.
ResolveNamesThis property determines whether the control resolves the host name for each host during the trace.
TimeoutThe timeout for the control.

Method List


The following is the full list of the methods of the control with short descriptions. Click on the links for further details.

ConfigSets or retrieves a configuration setting.
DoEventsThis method processes events from the internal message queue.
InterruptThis method interrupts the current method.
ResetThis method will reset the control.
ResolveRemoteHostThis method resolves the hostname in RemoteHost to an IP address.
TraceToThis method traces the route to a host.

Event List


The following is the full list of the events fired by the control with short descriptions. Click on the links for further details.

ErrorFired when information is available about errors during data delivery.
HopThis event is fired for each hop in the trace to the RemoteHost .
HopResolvedThis event is fired when the name of a hop address is found.

Config Settings


The following is a list of config settings for the control with short descriptions. Click on the links for further details.

DelayHostResolutionWhether the hostname is resolved when RemoteHost is set.
HopTimeoutInMillisecondsThe hop timeout is treated as milliseconds.
TimeoutInMillisecondsThe timeout is treated as milliseconds.
DelayHostResolutionWhether the hostname is resolved when RemoteHost is set.
DontFragmentWhether the DontFragment control flag is set.
IcmpDllTimeoutThe timeout for the control when using the icmp.dll.
MaxMessageSizeThe maximum length of the messages that can be received.
MulticastTTLThe time to live (TTL) value for multicast ICMP packets sent by the control.
ReceiveAllModeEnables a socket to receive all IPv4 or IPv6 packets on the network.
TimeoutInMillisecondsThe timeout is treated as milliseconds.
UseConnectionDetermines whether to use a connected socket.
UseICMPDLLUse the icmp.dll included on Windows Systems.
UseIPHLPDLLUse the iphlpapi.dll included on Windows Systems.
UseIPv6Whether to use IPv6.
AbsoluteTimeoutDetermines whether timeouts are inactivity timeouts or absolute timeouts.
FirewallDataUsed to send extra data to the firewall.
InBufferSizeThe size in bytes of the incoming queue of the socket.
OutBufferSizeThe size in bytes of the outgoing queue of the socket.
CodePageThe system code page used for Unicode to Multibyte translations.
MaskSensitiveDataWhether sensitive data is masked in log messages.
UseInternalSecurityAPIWhether or not to use the system security libraries or an internal implementation.

HopLimit Property (TraceRoute Control)

This property includes the maximum number of hops to allow for a trace.

Syntax

traceroutecontrol.HopLimit[=integer]

Default Value

64

Remarks

This property is used to limit lengthy traces. A value of 0 indicates an unbounded trace.

Note: If the value of Timeout is 0, an unbounded trace may cause a call to TraceTo to block indefinitely. To cancel such a route trace, call Interrupt.

Data Type

Integer

HopCount Property (TraceRoute Control)

The number of records in the Hop arrays.

Syntax

traceroutecontrol.HopCount

Default Value

0

Remarks

This property controls the size of the following arrays:

The array indices start at 0 and end at HopCount - 1.

This property is read-only and not available at design time.

Data Type

Integer

HopErrorCode Property (TraceRoute Control)

This property contains the error code for a particular hop in the trace.

Syntax

traceroutecontrol.HopErrorCode(HopIndex)

Default Value

0

Remarks

This property contains the error code for a particular hop in the trace.

For a list of valid error codes and their descriptions, please refer to the Error Messages section.

The HopIndex parameter specifies the index of the item in the array. The size of the array is controlled by the HopCount property.

This property is read-only and not available at design time.

Data Type

Integer

HopErrorDescription Property (TraceRoute Control)

This property contains the error description for a particular hop in the trace.

Syntax

traceroutecontrol.HopErrorDescription(HopIndex)

Default Value

""

Remarks

This property contains the error description for a particular hop in the trace.

For a list of valid error codes and their descriptions, please refer to the Error Messages section.

The HopIndex parameter specifies the index of the item in the array. The size of the array is controlled by the HopCount property.

This property is read-only and not available at design time.

Data Type

String

HopHostAddress Property (TraceRoute Control)

This property contains the IP address of the host for a particular hop in the trace.

Syntax

traceroutecontrol.HopHostAddress(HopIndex)

Default Value

""

Remarks

This property contains the IP address of the host for a particular hop in the trace.

The HopIndex parameter specifies the index of the item in the array. The size of the array is controlled by the HopCount property.

This property is read-only and not available at design time.

Data Type

String

HopHostName Property (TraceRoute Control)

This property contains the name of the host for a particular hop in the trace.

Syntax

traceroutecontrol.HopHostName(HopIndex)

Default Value

""

Remarks

This property contains the name of the host for a particular hop in the trace.

If ResolveNames is False, this property contains the IP address of the host instead.

The HopIndex parameter specifies the index of the item in the array. The size of the array is controlled by the HopCount property.

This property is read-only and not available at design time.

Data Type

String

HopTime Property (TraceRoute Control)

This property contains the amount of time taken by a particular hop in the trace.

Syntax

traceroutecontrol.HopTime(HopIndex)

Default Value

0

Remarks

This property contains the amount of time taken by a particular hop in the trace.

If a given hop times out, this value will be set to -1.

The HopIndex parameter specifies the index of the item in the array. The size of the array is controlled by the HopCount property.

This property is read-only and not available at design time.

Data Type

Integer

HopTimeout Property (TraceRoute Control)

This property includes the maximum amount of time to wait for an individual hop to complete.

Syntax

traceroutecontrol.HopTimeout[=integer]

Default Value

10

Remarks

The time value is in seconds. If 0, HopTimeout will be ignored, and only the Timeout for the whole trace will be taken into account.

Data Type

Integer

Idle Property (TraceRoute Control)

The current status of the control.

Syntax

traceroutecontrol.Idle

Default Value

True

Remarks

This property will be False if the component is currently busy (communicating or waiting for an answer), and True at all other times.

This property is read-only.

Data Type

Boolean

LocalHost Property (TraceRoute Control)

The name of the local host or user-assigned IP interface through which connections are initiated or accepted.

Syntax

traceroutecontrol.LocalHost[=string]

Default Value

""

Remarks

This property contains the name of the local host as obtained by the gethostname() system call, or if the user has assigned an IP address, the value of that address.

In multihomed hosts (machines with more than one IP interface) setting LocalHost to the IP address of an interface will make the control initiate connections (or accept in the case of server controls) only through that interface. It is recommended to provide an IP address rather than a hostname when setting this property to ensure the desired interface is used.

If the control is connected, the LocalHost property shows the IP address of the interface through which the connection is made in internet dotted format (aaa.bbb.ccc.ddd). In most cases, this is the address of the local host, except for multihomed hosts (machines with more than one IP interface).

Note: LocalHost is not persistent. You must always set it in code, and never in the property window.

Data Type

String

RemoteHost Property (TraceRoute Control)

This property includes the address of a host to trace to.

Syntax

traceroutecontrol.RemoteHost[=string]

Default Value

""

Remarks

Traces are initiated by setting RemoteHost to the name or address of the host to trace to.

This property must contain a valid Internet domain name or address or an error will be returned.

To interrupt a trace in progress, set RemoteHost to empty string.

Example. Perform a TraceRoute:

TraceRouteControl.TraceTo("myHost") is equivalent to TraceRouteControl.RemoteHost = "myHost"

Data Type

String

ResolveNames Property (TraceRoute Control)

This property determines whether the control resolves the host name for each host during the trace.

Syntax

traceroutecontrol.ResolveNames[=boolean]

Default Value

False

Remarks

This property determines whether the control resolves the name of host at each "hop" during the trace. The default value is False.

Note: If this property is set to True, the trace takes longer because of name resolution.

Data Type

Boolean

Timeout Property (TraceRoute Control)

The timeout for the control.

Syntax

traceroutecontrol.Timeout[=integer]

Default Value

60

Remarks

If the Timeout property is set to 0, all operations will run uninterrupted until successful completion or an error condition is encountered.

If Timeout is set to a positive value, the control will wait for the operation to complete before returning control.

The control will use DoEvents to enter an efficient wait loop during any potential waiting period, making sure that all system events are processed immediately as they arrive. This ensures that the host application does not freeze and remains responsive.

If Timeout expires, and the operation is not yet complete, the control fails with an error.

Note: By default, all timeouts are inactivity timeouts, that is, the timeout period is extended by Timeout seconds when any amount of data is successfully sent or received.

The default value for the Timeout property is 60 seconds.

Data Type

Integer

Config Method (TraceRoute Control)

Sets or retrieves a configuration setting.

Syntax

traceroutecontrol.Config ConfigurationString

Remarks

Config is a generic method available in every control. It is used to set and retrieve configuration settings for the control.

These settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.

To set a configuration setting named PROPERTY, you must call Config("PROPERTY=VALUE"), where VALUE is the value of the setting expressed as a string. For boolean values, use the strings "True", "False", "0", "1", "Yes", or "No" (case does not matter).

To read (query) the value of a configuration setting, you must call Config("PROPERTY"). The value will be returned as a string.

DoEvents Method (TraceRoute Control)

This method processes events from the internal message queue.

Syntax

traceroutecontrol.DoEvents 

Remarks

When DoEvents is called, the control processes any available events. If no events are available, it waits for a preset period of time, and then returns.

Interrupt Method (TraceRoute Control)

This method interrupts the current method.

Syntax

traceroutecontrol.Interrupt 

Remarks

If there is no method in progress, Interrupt simply returns, doing nothing.

Reset Method (TraceRoute Control)

This method will reset the control.

Syntax

traceroutecontrol.Reset 

Remarks

This method will reset the control's properties to their default values.

ResolveRemoteHost Method (TraceRoute Control)

This method resolves the hostname in RemoteHost to an IP address.

Syntax

traceroutecontrol.ResolveRemoteHost 

Remarks

This method resolves the hostname specified by RemoteHost to an IP address. The resolved value is available in the RemoteHost property after this method returns.

In most cases, calling this method is not necessary; the control will resolve the hostname automatically when needed. If DelayHostResolution is , this method may be called to manually resolve RemoteHost, if desired.

TraceTo Method (TraceRoute Control)

This method traces the route to a host.

Syntax

traceroutecontrol.TraceTo Host

Remarks

Traces are initiated by calling TraceTo, with the Host argument set to the name or address of the destination host to trace to. Host must contain a valid Internet domain name or address, or the control fails with an error. To interrupt a trace in progress, set RemoteHost to empty string. Calling this method is equivalent to setting the RemoteHost property to Host.

Example. Perform a TraceRoute:

TraceRouteControl.TraceTo("myHost") is equivalent to TraceRouteControl.RemoteHost = "myHost"

Error Event (TraceRoute Control)

Fired when information is available about errors during data delivery.

Syntax

Sub traceroutecontrol_Error(ErrorCode As Integer, Description As String)

Remarks

The Error event is fired in case of exceptional conditions during message processing. Normally the control fails with an error.

The ErrorCode parameter contains an error code, and the Description parameter contains a textual description of the error. For a list of valid error codes and their descriptions, please refer to the Error Codes section.

Hop Event (TraceRoute Control)

This event is fired for each hop in the trace to the RemoteHost .

Syntax

Sub traceroutecontrol_Hop(HopNumber As Integer, HostAddress As String, Duration As Integer)

Remarks

This event provides access to the information for each hop in the trace. The HopNumber parameter denotes which hop the trace is at. The HostAddress parameter is the IP address of the host for the hop identified by HopNumber. The Duration parameter shows the amount of time taken by the hop.

HopResolved Event (TraceRoute Control)

This event is fired when the name of a hop address is found.

Syntax

Sub traceroutecontrol_HopResolved(HopNumber As Integer, StatusCode As Integer, HopHostName As String)

Remarks

The StatusCode contains 0 if the address is resolved successfully, or an error code, in which case, HopHostName contains a textual description of the error.

Host name resolution is disabled by default. Set ResolveNames to True to enable it.

Config Settings (TraceRoute Control)

The control accepts one or more of the following configuration settings. Configuration settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.

TraceRoute Config Settings

DelayHostResolution:   Whether the hostname is resolved when RemoteHost is set.

This configuration setting specifies whether a hostname is resolved immediately when RemoteHost is set. If the control will resolve the hostname and the IP address will be present in the RemoteHost property. If , the hostname is not resolved until needed by the component when a method to connect or send data is called. If desired, ResolveRemoteHost may be called to manually resolve the value in RemoteHost at any time.

The default value is .

HopTimeoutInMilliseconds:   The hop timeout is treated as milliseconds.

Setting HopTimeoutInMilliseconds to True causes the control to use the value in the HopTimeout property as milliseconds instead of seconds, which is the default.

TimeoutInMilliseconds:   The timeout is treated as milliseconds.

Setting TimeoutInMilliseconds to True causes the control to use the value in the Timeout property as milliseconds instead of seconds, which is the default.

ICMP Config Settings

DelayHostResolution:   Whether the hostname is resolved when RemoteHost is set.

This configuration setting specifies whether a hostname is resolved immediately when RemoteHost is set. If the control will resolve the hostname and the IP address will be present in the RemoteHost property. If , the hostname is not resolved until needed by the component when a method to connect or send data is called. If desired, ResolveRemoteHost may be called to manually resolve the value in RemoteHost at any time.

The default value is .

DontFragment:   Whether the DontFragment control flag is set.

When set to True, the DontFragment control flag in the IP header will be set.

The default value is False.

IcmpDllTimeout:   The timeout for the control when using the icmp.dll.

The control will wait for the operation to complete before returning control. If IcmpDllTimeout expires, and the operation is not yet complete, the control fails with an error. IcmpDllTimeout must be set to a positive value.

The default value for IcmpDllTimeout is 60 seconds.

Note: This configuration setting is valid only when UseICMPDLL is set to True.

MaxMessageSize:   The maximum length of the messages that can be received.

This setting specifies the maximum size of the datagrams that the control will accept without truncation.

MulticastTTL:   The time to live (TTL) value for multicast ICMP packets sent by the component.

When sending multicast packets, the setting specifies the time-to-live (TTL) field. The TTL field of the ICMP packet is a counter limiting the lifetime of a packet.

Each router (or other module) that handles a packet decrements the TTL field by one or more if it holds the packet for more than one second. Thus, the TTL is effectively a hop count limit on how far a datagram can propagate through the internet. When the TTL is reduced to zero (or less), the packet is discarded.

By default, the default TTL value of the underlying Transmission Control Protocol (TCP)/IP subsystem will be used.

ReceiveAllMode:   Enables a socket to receive all IPv4 or IPv6 packets on the network.

This setting specifies the ReceiveAll mode for the socket. The following modes are available:

ValueDescription
-1 (default)The socket option is left unspecified.
0Do not receive all network traffic.
1Receive all network traffic. This enables the promiscuous mode on the network interface card (NIC). On a LAN segment with a network hub, a NIC that supports the promiscuous mode will capture all IPv4 or IPv6 traffic on the LAN, including traffic between other computers on the same LAN segment.
2Receive only socket-level network traffic (this feature may not be implemented by your Windows installation).
3Receive only IP-level network traffic. This option does not enable the promiscuous mode on the NIC. This option affects packet processing only at the IP level. The NIC still receives only those packets directed to its configured unicast and multicast addresses. A socket with this option enabled, however, not only will receive packets directed to specific IP addresses, but also will receive all the IPv4 or IPv6 packets the NIC receives.
TimeoutInMilliseconds:   The timeout is treated as milliseconds.

Setting TimeoutInMilliseconds to True causes the control to use the value in the IcmpDllTimeout configuration setting as milliseconds instead of seconds, which is the default.

Note: This setting is valid only when UseICMPDLL is set to True.

UseConnection:   Determines whether to use a connected socket.

UseConnection specifies whether or not the control should use a connected socket. The connection is defined as an association in between the local address/port and the remote address/port. As such, this is not a connection in the traditional Transmission Control Protocol (TCP) sense. It means only that the control will send and receive data to and from the specified destination.

The default value for this setting is False.

UseICMPDLL:   Use the icmp.dll included on Windows Systems.

Setting UseICMPDLL to True causes the control to use the icmp.dll on Windows 9x or on later machines. This sometimes enables access to raw sockets when permissions for standard operations are prohibited.

UseIPHLPDLL:   Use the iphlpapi.dll included on Windows Systems.

Setting UseIPHLPDLL to True causes the control to use the iphlpapi.dll on Windows XP or on later machines. This sometimes enables access to raw sockets when permissions for standard operations are prohibited.

Note: If both this and UseICMPDLL are enabled, the iphlpapi.dll will take precedence.

UseIPv6:   Whether to use IPv6.

When set to 0 (default), the control will use IPv4 exclusively. When set to 1, the control will use IPv6 exclusively. To instruct the control to prefer IPv6 addresses, but use IPv4 if IPv6 is not supported on the system, this setting should be set to 2. The default value is 0. Possible values are as follows:

0 IPv4 only
1 IPv6 only
2 IPv6 with IPv4 fallback

Socket Config Settings

AbsoluteTimeout:   Determines whether timeouts are inactivity timeouts or absolute timeouts.

If AbsoluteTimeout is set to True, any method that does not complete within Timeout seconds will be aborted. By default, AbsoluteTimeout is False, and the timeout is an inactivity timeout.

Note: This option is not valid for User Datagram Protocol (UDP) ports.

FirewallData:   Used to send extra data to the firewall.

When the firewall is a tunneling proxy, use this property to send custom (additional) headers to the firewall (e.g., headers for custom authentication schemes).

InBufferSize:   The size in bytes of the incoming queue of the socket.

This is the size of an internal queue in the Transmission Control Protocol (TCP)/IP stack. You can increase or decrease its size depending on the amount of data that you will be receiving. In some cases, increasing the value of the InBufferSize setting can provide significant improvements in performance.

Some TCP/IP implementations do not support variable buffer sizes. If that is the case, when the control is activated the InBufferSize reverts to its defined size. The same happens if you attempt to make it too large or too small.

OutBufferSize:   The size in bytes of the outgoing queue of the socket.

This is the size of an internal queue in the TCP/IP stack. You can increase or decrease its size depending on the amount of data that you will be sending. In some cases, increasing the value of the OutBufferSize setting can provide significant improvements in performance.

Some TCP/IP implementations do not support variable buffer sizes. If that is the case, when the control is activated the OutBufferSize reverts to its defined size. The same happens if you attempt to make it too large or too small.

Base Config Settings

CodePage:   The system code page used for Unicode to Multibyte translations.

The default code page is Unicode UTF-8 (65001).

The following is a list of valid code page identifiers:

IdentifierName
037IBM EBCDIC - U.S./Canada
437OEM - United States
500IBM EBCDIC - International
708Arabic - ASMO 708
709Arabic - ASMO 449+, BCON V4
710Arabic - Transparent Arabic
720Arabic - Transparent ASMO
737OEM - Greek (formerly 437G)
775OEM - Baltic
850OEM - Multilingual Latin I
852OEM - Latin II
855OEM - Cyrillic (primarily Russian)
857OEM - Turkish
858OEM - Multilingual Latin I + Euro symbol
860OEM - Portuguese
861OEM - Icelandic
862OEM - Hebrew
863OEM - Canadian-French
864OEM - Arabic
865OEM - Nordic
866OEM - Russian
869OEM - Modern Greek
870IBM EBCDIC - Multilingual/ROECE (Latin-2)
874ANSI/OEM - Thai (same as 28605, ISO 8859-15)
875IBM EBCDIC - Modern Greek
932ANSI/OEM - Japanese, Shift-JIS
936ANSI/OEM - Simplified Chinese (PRC, Singapore)
949ANSI/OEM - Korean (Unified Hangul Code)
950ANSI/OEM - Traditional Chinese (Taiwan; Hong Kong SAR, PRC)
1026IBM EBCDIC - Turkish (Latin-5)
1047IBM EBCDIC - Latin 1/Open System
1140IBM EBCDIC - U.S./Canada (037 + Euro symbol)
1141IBM EBCDIC - Germany (20273 + Euro symbol)
1142IBM EBCDIC - Denmark/Norway (20277 + Euro symbol)
1143IBM EBCDIC - Finland/Sweden (20278 + Euro symbol)
1144IBM EBCDIC - Italy (20280 + Euro symbol)
1145IBM EBCDIC - Latin America/Spain (20284 + Euro symbol)
1146IBM EBCDIC - United Kingdom (20285 + Euro symbol)
1147IBM EBCDIC - France (20297 + Euro symbol)
1148IBM EBCDIC - International (500 + Euro symbol)
1149IBM EBCDIC - Icelandic (20871 + Euro symbol)
1200Unicode UCS-2 Little-Endian (BMP of ISO 10646)
1201Unicode UCS-2 Big-Endian
1250ANSI - Central European
1251ANSI - Cyrillic
1252ANSI - Latin I
1253ANSI - Greek
1254ANSI - Turkish
1255ANSI - Hebrew
1256ANSI - Arabic
1257ANSI - Baltic
1258ANSI/OEM - Vietnamese
1361Korean (Johab)
10000MAC - Roman
10001MAC - Japanese
10002MAC - Traditional Chinese (Big5)
10003MAC - Korean
10004MAC - Arabic
10005MAC - Hebrew
10006MAC - Greek I
10007MAC - Cyrillic
10008MAC - Simplified Chinese (GB 2312)
10010MAC - Romania
10017MAC - Ukraine
10021MAC - Thai
10029MAC - Latin II
10079MAC - Icelandic
10081MAC - Turkish
10082MAC - Croatia
12000Unicode UCS-4 Little-Endian
12001Unicode UCS-4 Big-Endian
20000CNS - Taiwan
20001TCA - Taiwan
20002Eten - Taiwan
20003IBM5550 - Taiwan
20004TeleText - Taiwan
20005Wang - Taiwan
20105IA5 IRV International Alphabet No. 5 (7-bit)
20106IA5 German (7-bit)
20107IA5 Swedish (7-bit)
20108IA5 Norwegian (7-bit)
20127US-ASCII (7-bit)
20261T.61
20269ISO 6937 Non-Spacing Accent
20273IBM EBCDIC - Germany
20277IBM EBCDIC - Denmark/Norway
20278IBM EBCDIC - Finland/Sweden
20280IBM EBCDIC - Italy
20284IBM EBCDIC - Latin America/Spain
20285IBM EBCDIC - United Kingdom
20290IBM EBCDIC - Japanese Katakana Extended
20297IBM EBCDIC - France
20420IBM EBCDIC - Arabic
20423IBM EBCDIC - Greek
20424IBM EBCDIC - Hebrew
20833IBM EBCDIC - Korean Extended
20838IBM EBCDIC - Thai
20866Russian - KOI8-R
20871IBM EBCDIC - Icelandic
20880IBM EBCDIC - Cyrillic (Russian)
20905IBM EBCDIC - Turkish
20924IBM EBCDIC - Latin-1/Open System (1047 + Euro symbol)
20932JIS X 0208-1990 & 0121-1990
20936Simplified Chinese (GB2312)
21025IBM EBCDIC - Cyrillic (Serbian, Bulgarian)
21027Extended Alpha Lowercase
21866Ukrainian (KOI8-U)
28591ISO 8859-1 Latin I
28592ISO 8859-2 Central Europe
28593ISO 8859-3 Latin 3
28594ISO 8859-4 Baltic
28595ISO 8859-5 Cyrillic
28596ISO 8859-6 Arabic
28597ISO 8859-7 Greek
28598ISO 8859-8 Hebrew
28599ISO 8859-9 Latin 5
28605ISO 8859-15 Latin 9
29001Europa 3
38598ISO 8859-8 Hebrew
50220ISO 2022 Japanese with no halfwidth Katakana
50221ISO 2022 Japanese with halfwidth Katakana
50222ISO 2022 Japanese JIS X 0201-1989
50225ISO 2022 Korean
50227ISO 2022 Simplified Chinese
50229ISO 2022 Traditional Chinese
50930Japanese (Katakana) Extended
50931US/Canada and Japanese
50933Korean Extended and Korean
50935Simplified Chinese Extended and Simplified Chinese
50936Simplified Chinese
50937US/Canada and Traditional Chinese
50939Japanese (Latin) Extended and Japanese
51932EUC - Japanese
51936EUC - Simplified Chinese
51949EUC - Korean
51950EUC - Traditional Chinese
52936HZ-GB2312 Simplified Chinese
54936Windows XP: GB18030 Simplified Chinese (4 Byte)
57002ISCII Devanagari
57003ISCII Bengali
57004ISCII Tamil
57005ISCII Telugu
57006ISCII Assamese
57007ISCII Oriya
57008ISCII Kannada
57009ISCII Malayalam
57010ISCII Gujarati
57011ISCII Punjabi
65000Unicode UTF-7
65001Unicode UTF-8
The following is a list of valid code page identifiers for Mac OS only:
IdentifierName
1ASCII
2NEXTSTEP
3JapaneseEUC
4UTF8
5ISOLatin1
6Symbol
7NonLossyASCII
8ShiftJIS
9ISOLatin2
10Unicode
11WindowsCP1251
12WindowsCP1252
13WindowsCP1253
14WindowsCP1254
15WindowsCP1250
21ISO2022JP
30MacOSRoman
10UTF16String
0x90000100UTF16BigEndian
0x94000100UTF16LittleEndian
0x8c000100UTF32String
0x98000100UTF32BigEndian
0x9c000100UTF32LittleEndian
65536Proprietary

MaskSensitiveData:   Whether sensitive data is masked in log messages.

In certain circumstances it may be beneficial to mask sensitive data, like passwords, in log messages. Set this to to mask sensitive data. The default is .

This setting only works on these controls: AS3Receiver, AS3Sender, Atom, Client(3DS), FTP, FTPServer, IMAP, OFTPClient, SSHClient, SCP, Server(3DS), Sexec, SFTP, SFTPServer, SSHServer, TCPClient, TCPServer.

UseInternalSecurityAPI:   Whether or not to use the system security libraries or an internal implementation.

When set to , the control will use the system security libraries by default to perform cryptographic functions where applicable.

Setting this configuration setting to tells the control to use the internal implementation instead of using the system security libraries.

This setting is set to by default on all platforms.

Trappable Errors (TraceRoute Control)

TraceRoute Errors

20132    Request queue is full.
20133    Message for unknown request.
20135    Invalid address string.
20160    Invalid hop index (out of range).
20302    Timeout.
32303    Hop timed out.
32313    Busy performing current trace.

The control may also return one of the following error codes, which are inherited from other controls.

ICMP Errors

20105    The control is already Active.
20108    Cannot change the LocalHost at this time. A connection is in progress.
20110    The control must be Active for this operation.
20113    Cannot change MaxMessageSize while ICMP is Active.
20115    Cannot change RemoteHost when UseConnection is set and the control is Active.
20118    Cannot change UseConnection while the control is Active.
20119    The message cannot be longer than MaxMessageSize.
20120    The message is too short.
20121    Cannot create ICMP handle.

SSL Errors

20271    Cannot load specified security library.
20272    Cannot open certificate store.
20273    Cannot find specified certificate.
20274    Cannot acquire security credentials.
20275    Cannot find certificate chain.
20276    Cannot verify certificate chain.
20277    Error during handshake.
20281    Error verifying certificate.
20282    Could not find client certificate.
20283    Could not find server certificate.
20284    Error encrypting data.
20285    Error decrypting data.

TCP/IP Errors

25005    [10004] Interrupted system call.
25010    [10009] Bad file number.
25014    [10013] Access denied.
25015    [10014] Bad address.
25023    [10022] Invalid argument.
25025    [10024] Too many open files.
25036    [10035] Operation would block.
25037    [10036] Operation now in progress.
25038    [10037] Operation already in progress.
25039    [10038] Socket operation on nonsocket.
25040    [10039] Destination address required.
25041    [10040] Message is too long.
25042    [10041] Protocol wrong type for socket.
25043    [10042] Bad protocol option.
25044    [10043] Protocol is not supported.
25045    [10044] Socket type is not supported.
25046    [10045] Operation is not supported on socket.
25047    [10046] Protocol family is not supported.
25048    [10047] Address family is not supported by protocol family.
25049    [10048] Address already in use.
25050    [10049] Cannot assign requested address.
25051    [10050] Network is down.
25052    [10051] Network is unreachable.
25053    [10052] Net dropped connection or reset.
25054    [10053] Software caused connection abort.
25055    [10054] Connection reset by peer.
25056    [10055] No buffer space available.
25057    [10056] Socket is already connected.
25058    [10057] Socket is not connected.
25059    [10058] Cannot send after socket shutdown.
25060    [10059] Too many references, cannot splice.
25061    [10060] Connection timed out.
25062    [10061] Connection refused.
25063    [10062] Too many levels of symbolic links.
25064    [10063] File name is too long.
25065    [10064] Host is down.
25066    [10065] No route to host.
25067    [10066] Directory is not empty
25068    [10067] Too many processes.
25069    [10068] Too many users.
25070    [10069] Disc Quota Exceeded.
25071    [10070] Stale NFS file handle.
25072    [10071] Too many levels of remote in path.
25092    [10091] Network subsystem is unavailable.
25093    [10092] WINSOCK DLL Version out of range.
25094    [10093] Winsock is not loaded yet.
26002    [11001] Host not found.
26003    [11002] Nonauthoritative 'Host not found' (try again or check DNS setup).
26004    [11003] Nonrecoverable errors: FORMERR, REFUSED, NOTIMP.
26005    [11004] Valid name, no data record (check DNS setup).