Rshell Configuration
The control accepts one or more of the following configuration settings. Configuration settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.Rexec/Rshell Configuration Settings
EnableStderr: Enables or disables secondary (stderr) stream.Some systems (most notably certain versions of Linux) do not support
the secondary stderr stream of rexec/rshell. For these systems you must
turn stderr off. Any stderr output will then be provided through
stdout.
The default value for this setting is True. | |
StderrPort: The local port from which the remote system sends the stderr stream.The default value is 0, which instructs the control to use a
random port. Use this property with caution. If you supply a value,
it must be an available port on the system or an error will be returned.
Some systems do not support secondary stderr streams. Please refer to the EnableStderr configuration setting for more information. | |
MaxStdout: Maximum storage available for the stdout buffer.This indicates the maximum amount of characters that the control will store in the Stdout property. The default value is -1, which indicates there is no maximum. A value of zero (0) will disable accumulation of stdout in the Stdout property, although the Stdout event will still continue to fire. | |
MaxStderr: Maximum storage available for the stderr buffer.This indicates the maximum amount of characters that the control will store in the Stderr property. The default value is -1, which indicates there is no maximum. A value of zero (0) will disable accumulation of stderr in the Stderr property, although the Stderr event will still continue to fire. |
IPPort Configuration Settings
ConnectionTimeout: Sets a separate timeout value for establishing a connection.When set, this configuration setting allows you to specify a different timeout value for establishing a connection. Otherwise, the control will use Timeout for establishing a connection and transmitting/receiving data. | |||||||||
FirewallAutoDetect: Tells the control whether or not to automatically detect and use firewall system settings, if available.This is the same as FirewallAutoDetect. This setting is provided for use by controls that do not directly expose Firewall properties. | |||||||||
FirewallHost: Name or IP address of firewall (optional).If a FirewallHost is given, requested connections will be authenticated through the specified firewall
when connecting.
If the FirewallHost setting is set to a Domain Name, a DNS request is initiated. Upon successful termination of the request, the FirewallHost setting is set to the corresponding address. If the search is not successful, an error is returned. NOTE: This is the same as FirewallHost. This setting is provided for use by controls that do not directly expose Firewall properties. | |||||||||
FirewallPassword: Password to be used if authentication is to be used when connecting through the firewall.If FirewallHost is specified, the FirewallUser and FirewallPassword settings
are used to connect and authenticate to the given firewall. If the authentication fails, the control fails with an error.
NOTE: This is the same as FirewallPassword. This setting is provided for use by controls that do not directly expose Firewall properties. | |||||||||
FirewallPort: The TCP port for the FirewallHost;.Note that the FirewallPort is set automatically when FirewallType is set to a valid value.
NOTE: This is the same as FirewallPort. This setting is provided for use by controls that do not directly expose Firewall properties. | |||||||||
FirewallType: Determines the type of firewall to connect through.The appropriate values are as follows:
NOTE: This is the same as FirewallType. This setting is provided for use by controls that do not directly expose Firewall properties. | |||||||||
FirewallUser: A user name if authentication is to be used connecting through a firewall.If the FirewallHost is specified, the FirewallUser and FirewallPassword
settings are used to connect and authenticate to the Firewall. If the authentication fails, the control fails with an error.
NOTE: This is the same as FirewallUser. This setting is provided for use by controls that do not directly expose Firewall properties. | |||||||||
KeepAliveTime: The inactivity time in milliseconds before a TCP keep-alive packet is sent.When set, TCPKeepAlive will automatically be set to true.
By default the operating system will determine the
time a connection is idle before a TCP keep-alive packet is sent. This system default if this value is not specified here is 2 hours. In many
cases a shorter interval is more useful. Set this value to the desired interval in milliseconds.
Note: This value is not applicable in Java. | |||||||||
KeepAliveInterval: The retry interval, in milliseconds, to be used when a TCP keep-alive packet is sent and no response is received.When set, TCPKeepAlive will automatically be set to true.
A TCP keep-alive packet will be sent after a period of inactivity as
defined by KeepAliveTime. If no acknowledgement is received from the remote host the keep-alive packet
will be re-sent. This setting specifies the interval at which the successive keep-alive packets are sent in milliseconds.
This system default if this value is not specified here is 1 second.
Note: This value is not applicable in Java or MAC. | |||||||||
Linger: When set to True, connections are terminated gracefully.This property controls how a connection is closed. The default is True.
In the case that Linger is True (default), there are two scenarios for determining how long the connection will linger. The first, if LingerTime is 0 (default), the system will attempt to send pending data for a connection until the default IP protocol timeout expires. In the second scenario, LingerTime is a positive value, the system will attempt to send pending data until the specified LingerTime is reached. If this attempt fails, then the system will reset the connection. The default behavior (which is also the default mode for stream sockets) might result in a long delay in closing the connection. Although the control returns control immediately, the system could hold system resources until all pending data is sent (even after your application closes). Setting this property to False forces an immediate disconnection. If you know that the other side has received all the data you sent (by a client acknowledgment, for example), setting this property to False might be the appropriate course of action. | |||||||||
LingerTime: Time in seconds to have the connection linger. LingerTime is the time, in seconds, to leave the socket connection linger. This value is 0 by default, which means it will use the default IP protocol timeout. | |||||||||
LocalHost: The name of the local host through which connections are initiated or accepted.
The LocalHost setting contains the name of the local host
as obtained by the gethostname() system call, or if the
user has assigned an IP address, the value of that address.
In multi-homed hosts (machines with more than one IP interface) setting LocalHost to the value of an interface will make the control initiate connections (or accept in the case of server controls) only through that interface. If the control is connected, the LocalHost setting shows the IP address of the interface through which the connection is made in internet dotted format (aaa.bbb.ccc.ddd). In most cases, this is the address of the local host, except for multi-homed hosts (machines with more than one IP interface). | |||||||||
LocalPort: The TCP port in the local host where the control binds.
This must be set before a connection is
attempted. It instructs the control to bind to a specific
port (or communication endpoint) in the local machine.
Setting this to 0 (default) enables the system to choose a port at random. The chosen port will be shown by LocalPort after the connection is established. LocalPort cannot be changed once a connection is made. Any attempt to set this when a connection is active will generate an error. This; setting is useful when trying to connect to services that require a trusted port in the client side. An example is the remote shell (rsh) service in UNIX systems. | |||||||||
MaxLineLength: The maximum amount of data to accumulate when no EOL is found.MaxLineLength is the size of an internal buffer, which holds received data while waiting for an EOL
string.
If an EOL string is found in the input stream before MaxLineLength bytes are received, the DataIn event is fired with the EOL parameter set to True, and the buffer is reset. If no EOL is found, and MaxLineLength bytes are accumulated in the buffer, the DataIn event is fired with the EOL parameter set to False, and the buffer is reset. The minimum value for MaxLineLength is 256 bytes. The default value is 2048 bytes. The maximum value is 65536 bytes. | |||||||||
MaxTransferRate: The transfer rate limit in bytes per second.This setting can be used to throttle outbound TCP traffic. Set this to the number of bytes to be sent per second. By default this is not set and there is no limit. | |||||||||
RecordLength: The length of received data records.If set to a positive value, this setting defines the length of data records to be received. The control will accumulate data
until RecordLength is reached and only then fire the DataIn event with data of length RecordLength.
This allows data to be received as records of known length. This value can be changed at any time, including within the DataIn event.
The default value is 0, meaning this setting is not used. | |||||||||
TCPKeepAlive: Determines whether or not the keep alive socket option is enabled.If set to true, the socket's keep-alive option is enabled and keep-alive packets will be sent periodically
to maintain the connection. Set KeepAliveTime and KeepAliveInterval to
configure the timing of the keep-alive packets.
Note: This value is not applicable in Java. | |||||||||
UseIPv6: Whether to use IPv6.When set to 0 (default), the control will use IPv4 exclusively.
When set to 1, the control will use IPv6 exclusively. To instruct the control to prefer IPv6 addresses, but use IPv4 if IPv6 is not supported on the system, this setting should be set to 2. The default value is 0.
Possible values are:
| |||||||||
TcpNoDelay: Whether or not to delay when sending packets.
When true, the socket will send all data that is ready to send at once. When
false, the socket will send smaller buffered packets of data at small intervals.
This is known as the Nagle algorithm.
By default, this config is set to false. |
Socket Configuration Settings
AbsoluteTimeout: Determines whether timeouts are inactivity timeouts or absolute timeouts.If AbsoluteTimeout is set to True, any method which does not complete within Timeout seconds
will be aborted. By default, AbsoluteTimeout is False, and the timeout is an inactivity timeout.
Note: This option is not valid for UDP ports. | |
FirewallData: Used to send extra data to the firewall.When the firewall is a tunneling proxy, use this property to send custom (additional) headers to the firewall (e.g. headers for custom authentication schemes). | |
InBufferSize: The size in bytes of the incoming queue of the socket.
This is the size of an internal queue in the TCP/IP stack.
You can increase or decrease its size depending on the amount
of data that you will be receiving. Increasing the value of the
InBufferSize setting can provide significant improvements in
performance in some cases.
Some TCP/IP implementations do not support variable buffer sizes. If that is the case, when the control is activated the InBufferSize reverts to its defined size. The same happens if you attempt to make it too large or too small. | |
OutBufferSize: The size in bytes of the outgoing queue of the socket.This is the size of an internal queue in the TCP/IP stack.
You can increase or decrease its size depending on the amount
of data that you will be sending. Increasing the value of the
OutBufferSize setting can provide significant improvements in
performance in some cases.
Some TCP/IP implementations do not support variable buffer sizes. If that is the case, when the control is activated the OutBufferSize reverts to its defined size. The same happens if you attempt to make it too large or too small. |
Base Configuration Settings
CodePage: The system code page used for Unicode to Multibyte translations.
The default code page is the Active Code Page (0).
The following is a list of valid code page identifiers:
|