Poly1305 Control

Properties   Methods   Events   Config Settings   Errors  

The Poly1305 control may be used to produce a MAC (or Tag) value using the Poly1305 algorithm.

Syntax

Poly1305

Remarks

The Poly1305 control implements the Poly1305 algorithm defined in RFC 7539. This may be used to compute a MAC (or Tag) value on data of any length.

The Key must be set to a 256 bit (32 byte) key before computing the MAC. The computed MAC is 128 bit (32 bytes) in size.

ComputeMAC Notes

ComputeMAC computes the MAC (Message Authentication Code) from the input data.

Before calling this method set Key to a 256 bit (32 byte) key. If EncodeMAC is set to True (default) the output data will be hex encoded.

Input Notes

The control will determine the source of the input based on which properties are set.

The order in which the input properties are checked are as follows:

When a valid source is found the search stops.

After calling this method MACValue will be populated with the computed 128 bit (16 byte) value.

ComputeMAC Example

Poly1305 poly1305 = new Poly1305(); poly1305.KeyB = new byte[] { 0x1c, 0x92, 0x40, 0xa5, 0xeb, 0x55, 0xd3, 0x8a, 0xf3, 0x33, 0x88, 0x86, 0x04, 0xf6, 0xb5, 0xf0, 0x47, 0x39, 0x17, 0xc1, 0x40, 0x2b, 0x80, 0x09, 0x9d, 0xca, 0x5c, 0xbc, 0x20, 0x70, 0x75, 0xc0 }; poly1305.InputMessage = "Hello Polly"; poly1305.EncodeMAC = true; //hex output poly1305.ComputeMAC(); //This outputs "113019A3ACF5ED2FBB7A45AC1FD67DA1" Console.WriteLine(poly1305.MACValue);

ComputeMACBlock Notes

ComputeMACBlock allows input to the control to be specified in blocks. This method will return the MAC value only when the parameter LastBlock is True.

InputBuffer specifies the input data.

LastBlock specifies whether the block is the last block. If this is False the method will return an empty byte array.

To calculate the MAC value of data that is broken apart into multiple blocks make multiple calls to this method. For instance: //Encode output in hex poly1305.EncodeMAC = true; //hex output //Pass any number of parts, of any size poly1305.ComputeMACBlock(part1,false); poly1305.ComputeMACBlock(part2,false); poly1305.ComputeMACBlock(part3,false); //Pass true for the last block poly1305.ComputeMACBlock(lastPart,true); //The MACValue property holds the MAC value Console.WriteLine(poly1305.MACValue);

Property List


The following is the full list of the properties of the control with short descriptions. Click on the links for further details.

EncodeMACWhether the MAC value is hex encoded.
InputFileThe file to process.
InputMessageThe message to process.
KeyThe 256 bit (32 byte) key to be used when computing a MAC (Message Authentication Code).
MACValueThe computed MAC value.

Method List


The following is the full list of the methods of the control with short descriptions. Click on the links for further details.

ComputeMACComputes the MAC.
ComputeMACBlockComputes the MAC value of specified data.
ConfigSets or retrieves a configuration setting.
ResetResets the control.

Event List


The following is the full list of the events fired by the control with short descriptions. Click on the links for further details.

ErrorFired when information is available about errors during data delivery.
ProgressFired as progress is made.

Config Settings


The following is a list of config settings for the control with short descriptions. Click on the links for further details.

CodePageThe system code page used for Unicode to Multibyte translations.
MaskSensitiveDataWhether sensitive data is masked in log messages.
UseInternalSecurityAPIWhether or not to use the system security libraries or an internal implementation.

EncodeMAC Property (Poly1305 Control)

Whether the MAC value is hex encoded.

Syntax

poly1305control.EncodeMAC[=boolean]

Default Value

True

Remarks

This property specifies whether the computed MAC value is hex encoded. When set to True (default) the control will hex encoded the computed MAC for easier use. Set this value to False to obtain the MAC value in an unmodified form.

The default value is True.

Data Type

Boolean

InputFile Property (Poly1305 Control)

The file to process.

Syntax

poly1305control.InputFile[=string]

Default Value

""

Remarks

This property specifies the file to be processed. Set this property to the full or relative path to the file which will be processed.

Input and Output Properties

The control will determine the source and destination of the input and output based on which properties are set.

The order in which the input properties are checked is as follows:

When a valid source is found, the search stops. The order in which the output properties are checked is as follows:

  • OutputFile
  • OutputMessage: The output data is written to this property if no other destination is specified.

Data Type

String

InputMessage Property (Poly1305 Control)

The message to process.

Syntax

poly1305control.InputMessage[=string]

Default Value

""

Remarks

This property specifies the message to be processed.

Input and Output Properties

The control will determine the source and destination of the input and output based on which properties are set.

The order in which the input properties are checked is as follows:

When a valid source is found, the search stops. The order in which the output properties are checked is as follows:

  • OutputFile
  • OutputMessage: The output data is written to this property if no other destination is specified.

To read or write binary data to the property, a Variant (Byte Array) version is provided in .InputMessageB.

Data Type

Binary String

Key Property (Poly1305 Control)

The 256 bit (32 byte) key to be used when computing a MAC (Message Authentication Code).

Syntax

poly1305control.Key[=string]

Default Value

""

Remarks

This property holds the secret key used when computing the MACValue. The key must be 256 bits (32 bytes) long.

To read or write binary data to the property, a Variant (Byte Array) version is provided in .KeyB.

Data Type

Binary String

MACValue Property (Poly1305 Control)

The computed MAC value.

Syntax

poly1305control.MACValue

Default Value

""

Remarks

The 128 bit (16 byte) MAC value calculated after calling ComputeMAC.

To read or write binary data to the property, a Variant (Byte Array) version is provided in .MACValueB.

This property is read-only.

Data Type

Binary String

ComputeMAC Method (Poly1305 Control)

Computes the MAC.

Syntax

poly1305control.ComputeMAC 

Remarks

ComputeMAC computes the MAC (Message Authentication Code) from the input data.

Before calling this method set Key to a 256 bit (32 byte) key. If EncodeMAC is set to True (default) the output data will be hex encoded.

Input Notes

The control will determine the source of the input based on which properties are set.

The order in which the input properties are checked are as follows:

When a valid source is found the search stops.

After calling this method MACValue will be populated with the computed 128 bit (16 byte) value.

ComputeMAC Example

Poly1305 poly1305 = new Poly1305(); poly1305.KeyB = new byte[] { 0x1c, 0x92, 0x40, 0xa5, 0xeb, 0x55, 0xd3, 0x8a, 0xf3, 0x33, 0x88, 0x86, 0x04, 0xf6, 0xb5, 0xf0, 0x47, 0x39, 0x17, 0xc1, 0x40, 0x2b, 0x80, 0x09, 0x9d, 0xca, 0x5c, 0xbc, 0x20, 0x70, 0x75, 0xc0 }; poly1305.InputMessage = "Hello Polly"; poly1305.EncodeMAC = true; //hex output poly1305.ComputeMAC(); //This outputs "113019A3ACF5ED2FBB7A45AC1FD67DA1" Console.WriteLine(poly1305.MACValue);

ComputeMACBlock Method (Poly1305 Control)

Computes the MAC value of specified data.

Syntax

poly1305control.ComputeMACBlock InputBuffer, LastBlock

Remarks

ComputeMACBlock allows input to the control to be specified in blocks. This method will return the MAC value only when the parameter LastBlock is True.

InputBuffer specifies the input data.

LastBlock specifies whether the block is the last block. If this is False the method will return an empty byte array.

To calculate the MAC value of data that is broken apart into multiple blocks make multiple calls to this method. For instance: //Encode output in hex poly1305.EncodeMAC = true; //hex output //Pass any number of parts, of any size poly1305.ComputeMACBlock(part1,false); poly1305.ComputeMACBlock(part2,false); poly1305.ComputeMACBlock(part3,false); //Pass true for the last block poly1305.ComputeMACBlock(lastPart,true); //The MACValue property holds the MAC value Console.WriteLine(poly1305.MACValue);

Config Method (Poly1305 Control)

Sets or retrieves a configuration setting.

Syntax

poly1305control.Config ConfigurationString

Remarks

Config is a generic method available in every control. It is used to set and retrieve configuration settings for the control.

These settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.

To set a configuration setting named PROPERTY, you must call Config("PROPERTY=VALUE"), where VALUE is the value of the setting expressed as a string. For boolean values, use the strings "True", "False", "0", "1", "Yes", or "No" (case does not matter).

To read (query) the value of a configuration setting, you must call Config("PROPERTY"). The value will be returned as a string.

Reset Method (Poly1305 Control)

Resets the control.

Syntax

poly1305control.Reset 

Remarks

When called, the control will reset all of its properties to their default values.

Error Event (Poly1305 Control)

Fired when information is available about errors during data delivery.

Syntax

Sub poly1305control_Error(ErrorCode As Integer, Description As String)

Remarks

The Error event is fired in case of exceptional conditions during message processing. Normally the control fails with an error.

The ErrorCode parameter contains an error code, and the Description parameter contains a textual description of the error. For a list of valid error codes and their descriptions, please refer to the Error Codes section.

Progress Event (Poly1305 Control)

Fired as progress is made.

Syntax

Sub poly1305control_Progress(BytesProcessed As Long64, PercentProcessed As Integer)

Remarks

This event is fired automatically as data is processed by the control.

The PercentProcessed parameter indicates the current status of the operation.

The BytesProcessed parameter holds the total number of bytes processed so far.

Config Settings (Poly1305 Control)

The control accepts one or more of the following configuration settings. Configuration settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the control, access to these internal properties is provided through the Config method.

Base Config Settings

CodePage:   The system code page used for Unicode to Multibyte translations.

The default code page is Unicode UTF-8 (65001).

The following is a list of valid code page identifiers:

IdentifierName
037IBM EBCDIC - U.S./Canada
437OEM - United States
500IBM EBCDIC - International
708Arabic - ASMO 708
709Arabic - ASMO 449+, BCON V4
710Arabic - Transparent Arabic
720Arabic - Transparent ASMO
737OEM - Greek (formerly 437G)
775OEM - Baltic
850OEM - Multilingual Latin I
852OEM - Latin II
855OEM - Cyrillic (primarily Russian)
857OEM - Turkish
858OEM - Multilingual Latin I + Euro symbol
860OEM - Portuguese
861OEM - Icelandic
862OEM - Hebrew
863OEM - Canadian-French
864OEM - Arabic
865OEM - Nordic
866OEM - Russian
869OEM - Modern Greek
870IBM EBCDIC - Multilingual/ROECE (Latin-2)
874ANSI/OEM - Thai (same as 28605, ISO 8859-15)
875IBM EBCDIC - Modern Greek
932ANSI/OEM - Japanese, Shift-JIS
936ANSI/OEM - Simplified Chinese (PRC, Singapore)
949ANSI/OEM - Korean (Unified Hangul Code)
950ANSI/OEM - Traditional Chinese (Taiwan; Hong Kong SAR, PRC)
1026IBM EBCDIC - Turkish (Latin-5)
1047IBM EBCDIC - Latin 1/Open System
1140IBM EBCDIC - U.S./Canada (037 + Euro symbol)
1141IBM EBCDIC - Germany (20273 + Euro symbol)
1142IBM EBCDIC - Denmark/Norway (20277 + Euro symbol)
1143IBM EBCDIC - Finland/Sweden (20278 + Euro symbol)
1144IBM EBCDIC - Italy (20280 + Euro symbol)
1145IBM EBCDIC - Latin America/Spain (20284 + Euro symbol)
1146IBM EBCDIC - United Kingdom (20285 + Euro symbol)
1147IBM EBCDIC - France (20297 + Euro symbol)
1148IBM EBCDIC - International (500 + Euro symbol)
1149IBM EBCDIC - Icelandic (20871 + Euro symbol)
1200Unicode UCS-2 Little-Endian (BMP of ISO 10646)
1201Unicode UCS-2 Big-Endian
1250ANSI - Central European
1251ANSI - Cyrillic
1252ANSI - Latin I
1253ANSI - Greek
1254ANSI - Turkish
1255ANSI - Hebrew
1256ANSI - Arabic
1257ANSI - Baltic
1258ANSI/OEM - Vietnamese
1361Korean (Johab)
10000MAC - Roman
10001MAC - Japanese
10002MAC - Traditional Chinese (Big5)
10003MAC - Korean
10004MAC - Arabic
10005MAC - Hebrew
10006MAC - Greek I
10007MAC - Cyrillic
10008MAC - Simplified Chinese (GB 2312)
10010MAC - Romania
10017MAC - Ukraine
10021MAC - Thai
10029MAC - Latin II
10079MAC - Icelandic
10081MAC - Turkish
10082MAC - Croatia
12000Unicode UCS-4 Little-Endian
12001Unicode UCS-4 Big-Endian
20000CNS - Taiwan
20001TCA - Taiwan
20002Eten - Taiwan
20003IBM5550 - Taiwan
20004TeleText - Taiwan
20005Wang - Taiwan
20105IA5 IRV International Alphabet No. 5 (7-bit)
20106IA5 German (7-bit)
20107IA5 Swedish (7-bit)
20108IA5 Norwegian (7-bit)
20127US-ASCII (7-bit)
20261T.61
20269ISO 6937 Non-Spacing Accent
20273IBM EBCDIC - Germany
20277IBM EBCDIC - Denmark/Norway
20278IBM EBCDIC - Finland/Sweden
20280IBM EBCDIC - Italy
20284IBM EBCDIC - Latin America/Spain
20285IBM EBCDIC - United Kingdom
20290IBM EBCDIC - Japanese Katakana Extended
20297IBM EBCDIC - France
20420IBM EBCDIC - Arabic
20423IBM EBCDIC - Greek
20424IBM EBCDIC - Hebrew
20833IBM EBCDIC - Korean Extended
20838IBM EBCDIC - Thai
20866Russian - KOI8-R
20871IBM EBCDIC - Icelandic
20880IBM EBCDIC - Cyrillic (Russian)
20905IBM EBCDIC - Turkish
20924IBM EBCDIC - Latin-1/Open System (1047 + Euro symbol)
20932JIS X 0208-1990 & 0121-1990
20936Simplified Chinese (GB2312)
21025IBM EBCDIC - Cyrillic (Serbian, Bulgarian)
21027Extended Alpha Lowercase
21866Ukrainian (KOI8-U)
28591ISO 8859-1 Latin I
28592ISO 8859-2 Central Europe
28593ISO 8859-3 Latin 3
28594ISO 8859-4 Baltic
28595ISO 8859-5 Cyrillic
28596ISO 8859-6 Arabic
28597ISO 8859-7 Greek
28598ISO 8859-8 Hebrew
28599ISO 8859-9 Latin 5
28605ISO 8859-15 Latin 9
29001Europa 3
38598ISO 8859-8 Hebrew
50220ISO 2022 Japanese with no halfwidth Katakana
50221ISO 2022 Japanese with halfwidth Katakana
50222ISO 2022 Japanese JIS X 0201-1989
50225ISO 2022 Korean
50227ISO 2022 Simplified Chinese
50229ISO 2022 Traditional Chinese
50930Japanese (Katakana) Extended
50931US/Canada and Japanese
50933Korean Extended and Korean
50935Simplified Chinese Extended and Simplified Chinese
50936Simplified Chinese
50937US/Canada and Traditional Chinese
50939Japanese (Latin) Extended and Japanese
51932EUC - Japanese
51936EUC - Simplified Chinese
51949EUC - Korean
51950EUC - Traditional Chinese
52936HZ-GB2312 Simplified Chinese
54936Windows XP: GB18030 Simplified Chinese (4 Byte)
57002ISCII Devanagari
57003ISCII Bengali
57004ISCII Tamil
57005ISCII Telugu
57006ISCII Assamese
57007ISCII Oriya
57008ISCII Kannada
57009ISCII Malayalam
57010ISCII Gujarati
57011ISCII Punjabi
65000Unicode UTF-7
65001Unicode UTF-8
The following is a list of valid code page identifiers for Mac OS only:
IdentifierName
1ASCII
2NEXTSTEP
3JapaneseEUC
4UTF8
5ISOLatin1
6Symbol
7NonLossyASCII
8ShiftJIS
9ISOLatin2
10Unicode
11WindowsCP1251
12WindowsCP1252
13WindowsCP1253
14WindowsCP1254
15WindowsCP1250
21ISO2022JP
30MacOSRoman
10UTF16String
0x90000100UTF16BigEndian
0x94000100UTF16LittleEndian
0x8c000100UTF32String
0x98000100UTF32BigEndian
0x9c000100UTF32LittleEndian
65536Proprietary

MaskSensitiveData:   Whether sensitive data is masked in log messages.

In certain circumstances it may be beneficial to mask sensitive data, like passwords, in log messages. Set this to to mask sensitive data. The default is .

This setting only works on these controls: AS3Receiver, AS3Sender, Atom, Client(3DS), FTP, FTPServer, IMAP, OFTPClient, SSHClient, SCP, Server(3DS), Sexec, SFTP, SFTPServer, SSHServer, TCPClient, TCPServer.

UseInternalSecurityAPI:   Whether or not to use the system security libraries or an internal implementation.

When set to , the control will use the system security libraries by default to perform cryptographic functions where applicable.

Setting this configuration setting to tells the control to use the internal implementation instead of using the system security libraries.

This setting is set to by default on all platforms.

Trappable Errors (Poly1305 Control)

Poly1305 Errors

20105    Cannot read or write file.
20109    Invalid key size.
20305    Cannot write file.
20306    Cannot read file.