Poly1305 Component
Properties Methods Events Config Settings Errors
The Poly1305 component may be used to produce a MAC (or Tag) value using the Poly1305 algorithm.
Syntax
TipcPoly1305
Remarks
The Poly1305 component implements the Poly1305 algorithm defined in RFC 7539. This may be used to compute a MAC (or Tag) value on data of any length.
The Key must be set to a 256 bit (32 byte) key before computing the MAC. The computed MAC is 128 bit (32 bytes) in size.
ComputeMAC Notes
ComputeMAC computes the MAC (Message Authentication Code) from the input data.
Before calling this method set Key to a 256 bit (32 byte) key. If EncodeMAC is set to True (default) the output data will be hex encoded.
Input Notes
The component will determine the source of the input based on which properties are set.
The order in which the input properties are checked are as follows:
When a valid source is found the search stops.After calling this method MACValue will be populated with the computed 128 bit (16 byte) value.
ComputeMAC Example
Poly1305 poly1305 = new Poly1305();
poly1305.KeyB = new byte[] { 0x1c, 0x92, 0x40, 0xa5, 0xeb, 0x55, 0xd3, 0x8a, 0xf3, 0x33, 0x88, 0x86, 0x04, 0xf6, 0xb5, 0xf0, 0x47, 0x39, 0x17, 0xc1, 0x40, 0x2b, 0x80, 0x09, 0x9d, 0xca, 0x5c, 0xbc, 0x20, 0x70, 0x75, 0xc0 };
poly1305.InputMessage = "Hello Polly";
poly1305.EncodeMAC = true; //hex output
poly1305.ComputeMAC();
//This outputs "113019A3ACF5ED2FBB7A45AC1FD67DA1"
Console.WriteLine(poly1305.MACValue);
ComputeMACBlock Notes
ComputeMACBlock allows input to the component to be specified in blocks. This method will return the MAC value only when the parameter LastBlock is True.
InputBuffer specifies the input data.
LastBlock specifies whether the block is the last block. If this is False the method will return an empty byte array.
To calculate the MAC value of data that is broken apart into multiple blocks make multiple calls to this method. For instance:
//Encode output in hex
poly1305.EncodeMAC = true; //hex output
//Pass any number of parts, of any size
poly1305.ComputeMACBlock(part1,false);
poly1305.ComputeMACBlock(part2,false);
poly1305.ComputeMACBlock(part3,false);
//Pass true for the last block
poly1305.ComputeMACBlock(lastPart,true);
//The MACValue property holds the MAC value
Console.WriteLine(poly1305.MACValue);
Property List
The following is the full list of the properties of the component with short descriptions. Click on the links for further details.
EncodeMAC | Whether the MAC value is hex encoded. |
InputFile | The file to process. |
InputMessage | The message to process. |
Key | The 256 bit (32 byte) key to be used when computing a MAC (Message Authentication Code). |
MACValue | The computed MAC value. |
Method List
The following is the full list of the methods of the component with short descriptions. Click on the links for further details.
ComputeMAC | Computes the MAC. |
ComputeMACBlock | Computes the MAC value of specified data. |
Config | Sets or retrieves a configuration setting. |
Reset | Resets the component. |
Event List
The following is the full list of the events fired by the component with short descriptions. Click on the links for further details.
Error | Fired when information is available about errors during data delivery. |
Progress | Fired as progress is made. |
Config Settings
The following is a list of config settings for the component with short descriptions. Click on the links for further details.
BuildInfo | Information about the product's build. |
CodePage | The system code page used for Unicode to Multibyte translations. |
LicenseInfo | Information about the current license. |
MaskSensitiveData | Whether sensitive data is masked in log messages. |
UseFIPSCompliantAPI | Tells the component whether or not to use FIPS certified APIs. |
UseInternalSecurityAPI | Whether or not to use the system security libraries or an internal implementation. |
EncodeMAC Property (Poly1305 Component)
Whether the MAC value is hex encoded.
Syntax
__property bool EncodeMAC = { read=FEncodeMAC, write=FSetEncodeMAC };
Default Value
true
Remarks
This property specifies whether the computed MAC value is hex encoded. When set to True (default) the component will hex encoded the computed MAC for easier use. Set this value to False to obtain the MAC value in an unmodified form.
The default value is True.
Data Type
Boolean
InputFile Property (Poly1305 Component)
The file to process.
Syntax
__property String InputFile = { read=FInputFile, write=FSetInputFile };
Default Value
""
Remarks
This property specifies the file to be processed. Set this property to the full or relative path to the file which will be processed.
Input and Output Properties
The component will determine the source and destination of the input and output based on which properties are set.
The order in which the input properties are checked is as follows:
- InputFile
- InputMessage
When a valid source is found, the search stops. The order in which the output properties are checked is as follows:
- OutputFile
- OutputMessage: The output data is written to this property if no other destination is specified.
Data Type
String
InputMessage Property (Poly1305 Component)
The message to process.
Syntax
__property String InputMessage = { read=FInputMessage, write=FSetInputMessage }; __property DynamicArray<Byte> InputMessageB = { read=FInputMessageB, write=FSetInputMessageB };
Default Value
""
Remarks
This property specifies the message to be processed.
Input and Output Properties
The component will determine the source and destination of the input and output based on which properties are set.
The order in which the input properties are checked is as follows:
- InputFile
- InputMessage
When a valid source is found, the search stops. The order in which the output properties are checked is as follows:
- OutputFile
- OutputMessage: The output data is written to this property if no other destination is specified.
Data Type
Byte Array
Key Property (Poly1305 Component)
The 256 bit (32 byte) key to be used when computing a MAC (Message Authentication Code).
Syntax
__property String Key = { read=FKey, write=FSetKey }; __property DynamicArray<Byte> KeyB = { read=FKeyB, write=FSetKeyB };
Default Value
""
Remarks
This property holds the secret key used when computing the MACValue. The key must be 256 bits (32 bytes) long.
Data Type
Byte Array
MACValue Property (Poly1305 Component)
The computed MAC value.
Syntax
__property String MACValue = { read=FMACValue }; __property DynamicArray<Byte> MACValueB = { read=FMACValueB };
Default Value
""
Remarks
The 128 bit (16 byte) MAC value calculated after calling ComputeMAC.
This property is read-only.
Data Type
Byte Array
ComputeMAC Method (Poly1305 Component)
Computes the MAC.
Syntax
void __fastcall ComputeMAC();
Remarks
ComputeMAC computes the MAC (Message Authentication Code) from the input data.
Before calling this method set Key to a 256 bit (32 byte) key. If EncodeMAC is set to True (default) the output data will be hex encoded.
Input Notes
The component will determine the source of the input based on which properties are set.
The order in which the input properties are checked are as follows:
When a valid source is found the search stops.After calling this method MACValue will be populated with the computed 128 bit (16 byte) value.
ComputeMAC Example
Poly1305 poly1305 = new Poly1305();
poly1305.KeyB = new byte[] { 0x1c, 0x92, 0x40, 0xa5, 0xeb, 0x55, 0xd3, 0x8a, 0xf3, 0x33, 0x88, 0x86, 0x04, 0xf6, 0xb5, 0xf0, 0x47, 0x39, 0x17, 0xc1, 0x40, 0x2b, 0x80, 0x09, 0x9d, 0xca, 0x5c, 0xbc, 0x20, 0x70, 0x75, 0xc0 };
poly1305.InputMessage = "Hello Polly";
poly1305.EncodeMAC = true; //hex output
poly1305.ComputeMAC();
//This outputs "113019A3ACF5ED2FBB7A45AC1FD67DA1"
Console.WriteLine(poly1305.MACValue);
ComputeMACBlock Method (Poly1305 Component)
Computes the MAC value of specified data.
Syntax
DynamicArray<Byte> __fastcall ComputeMACBlock(DynamicArray<Byte> InputBuffer, bool LastBlock);
Remarks
ComputeMACBlock allows input to the component to be specified in blocks. This method will return the MAC value only when the parameter LastBlock is True.
InputBuffer specifies the input data.
LastBlock specifies whether the block is the last block. If this is False the method will return an empty byte array.
To calculate the MAC value of data that is broken apart into multiple blocks make multiple calls to this method. For instance:
//Encode output in hex
poly1305.EncodeMAC = true; //hex output
//Pass any number of parts, of any size
poly1305.ComputeMACBlock(part1,false);
poly1305.ComputeMACBlock(part2,false);
poly1305.ComputeMACBlock(part3,false);
//Pass true for the last block
poly1305.ComputeMACBlock(lastPart,true);
//The MACValue property holds the MAC value
Console.WriteLine(poly1305.MACValue);
Config Method (Poly1305 Component)
Sets or retrieves a configuration setting.
Syntax
String __fastcall Config(String ConfigurationString);
Remarks
Config is a generic method available in every component. It is used to set and retrieve configuration settings for the component.
These settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the component, access to these internal properties is provided through the Config method.
To set a configuration setting named PROPERTY, you must call Config("PROPERTY=VALUE"), where VALUE is the value of the setting expressed as a string. For boolean values, use the strings "True", "False", "0", "1", "Yes", or "No" (case does not matter).
To read (query) the value of a configuration setting, you must call Config("PROPERTY"). The value will be returned as a string.
Reset Method (Poly1305 Component)
Resets the component.
Syntax
void __fastcall Reset();
Remarks
When called, the component will reset all of its properties to their default values.
Error Event (Poly1305 Component)
Fired when information is available about errors during data delivery.
Syntax
typedef struct { int ErrorCode; String Description; } TipcPoly1305ErrorEventParams; typedef void __fastcall (__closure *TipcPoly1305ErrorEvent)(System::TObject* Sender, TipcPoly1305ErrorEventParams *e); __property TipcPoly1305ErrorEvent OnError = { read=FOnError, write=FOnError };
Remarks
The Error event is fired in case of exceptional conditions during message processing. Normally the component raises an exception.
The ErrorCode parameter contains an error code, and the Description parameter contains a textual description of the error. For a list of valid error codes and their descriptions, please refer to the Error Codes section.
Progress Event (Poly1305 Component)
Fired as progress is made.
Syntax
typedef struct { __int64 BytesProcessed; int PercentProcessed; } TipcPoly1305ProgressEventParams; typedef void __fastcall (__closure *TipcPoly1305ProgressEvent)(System::TObject* Sender, TipcPoly1305ProgressEventParams *e); __property TipcPoly1305ProgressEvent OnProgress = { read=FOnProgress, write=FOnProgress };
Remarks
This event is fired automatically as data is processed by the component.
The PercentProcessed parameter indicates the current status of the operation.
The BytesProcessed parameter holds the total number of bytes processed so far.
Config Settings (Poly1305 Component)
The component accepts one or more of the following configuration settings. Configuration settings are similar in functionality to properties, but they are rarely used. In order to avoid "polluting" the property namespace of the component, access to these internal properties is provided through the Config method.Base Config Settings
The following is a list of valid code page identifiers:
Identifier | Name |
037 | IBM EBCDIC - U.S./Canada |
437 | OEM - United States |
500 | IBM EBCDIC - International |
708 | Arabic - ASMO 708 |
709 | Arabic - ASMO 449+, BCON V4 |
710 | Arabic - Transparent Arabic |
720 | Arabic - Transparent ASMO |
737 | OEM - Greek (formerly 437G) |
775 | OEM - Baltic |
850 | OEM - Multilingual Latin I |
852 | OEM - Latin II |
855 | OEM - Cyrillic (primarily Russian) |
857 | OEM - Turkish |
858 | OEM - Multilingual Latin I + Euro symbol |
860 | OEM - Portuguese |
861 | OEM - Icelandic |
862 | OEM - Hebrew |
863 | OEM - Canadian-French |
864 | OEM - Arabic |
865 | OEM - Nordic |
866 | OEM - Russian |
869 | OEM - Modern Greek |
870 | IBM EBCDIC - Multilingual/ROECE (Latin-2) |
874 | ANSI/OEM - Thai (same as 28605, ISO 8859-15) |
875 | IBM EBCDIC - Modern Greek |
932 | ANSI/OEM - Japanese, Shift-JIS |
936 | ANSI/OEM - Simplified Chinese (PRC, Singapore) |
949 | ANSI/OEM - Korean (Unified Hangul Code) |
950 | ANSI/OEM - Traditional Chinese (Taiwan; Hong Kong SAR, PRC) |
1026 | IBM EBCDIC - Turkish (Latin-5) |
1047 | IBM EBCDIC - Latin 1/Open System |
1140 | IBM EBCDIC - U.S./Canada (037 + Euro symbol) |
1141 | IBM EBCDIC - Germany (20273 + Euro symbol) |
1142 | IBM EBCDIC - Denmark/Norway (20277 + Euro symbol) |
1143 | IBM EBCDIC - Finland/Sweden (20278 + Euro symbol) |
1144 | IBM EBCDIC - Italy (20280 + Euro symbol) |
1145 | IBM EBCDIC - Latin America/Spain (20284 + Euro symbol) |
1146 | IBM EBCDIC - United Kingdom (20285 + Euro symbol) |
1147 | IBM EBCDIC - France (20297 + Euro symbol) |
1148 | IBM EBCDIC - International (500 + Euro symbol) |
1149 | IBM EBCDIC - Icelandic (20871 + Euro symbol) |
1200 | Unicode UCS-2 Little-Endian (BMP of ISO 10646) |
1201 | Unicode UCS-2 Big-Endian |
1250 | ANSI - Central European |
1251 | ANSI - Cyrillic |
1252 | ANSI - Latin I |
1253 | ANSI - Greek |
1254 | ANSI - Turkish |
1255 | ANSI - Hebrew |
1256 | ANSI - Arabic |
1257 | ANSI - Baltic |
1258 | ANSI/OEM - Vietnamese |
1361 | Korean (Johab) |
10000 | MAC - Roman |
10001 | MAC - Japanese |
10002 | MAC - Traditional Chinese (Big5) |
10003 | MAC - Korean |
10004 | MAC - Arabic |
10005 | MAC - Hebrew |
10006 | MAC - Greek I |
10007 | MAC - Cyrillic |
10008 | MAC - Simplified Chinese (GB 2312) |
10010 | MAC - Romania |
10017 | MAC - Ukraine |
10021 | MAC - Thai |
10029 | MAC - Latin II |
10079 | MAC - Icelandic |
10081 | MAC - Turkish |
10082 | MAC - Croatia |
12000 | Unicode UCS-4 Little-Endian |
12001 | Unicode UCS-4 Big-Endian |
20000 | CNS - Taiwan |
20001 | TCA - Taiwan |
20002 | Eten - Taiwan |
20003 | IBM5550 - Taiwan |
20004 | TeleText - Taiwan |
20005 | Wang - Taiwan |
20105 | IA5 IRV International Alphabet No. 5 (7-bit) |
20106 | IA5 German (7-bit) |
20107 | IA5 Swedish (7-bit) |
20108 | IA5 Norwegian (7-bit) |
20127 | US-ASCII (7-bit) |
20261 | T.61 |
20269 | ISO 6937 Non-Spacing Accent |
20273 | IBM EBCDIC - Germany |
20277 | IBM EBCDIC - Denmark/Norway |
20278 | IBM EBCDIC - Finland/Sweden |
20280 | IBM EBCDIC - Italy |
20284 | IBM EBCDIC - Latin America/Spain |
20285 | IBM EBCDIC - United Kingdom |
20290 | IBM EBCDIC - Japanese Katakana Extended |
20297 | IBM EBCDIC - France |
20420 | IBM EBCDIC - Arabic |
20423 | IBM EBCDIC - Greek |
20424 | IBM EBCDIC - Hebrew |
20833 | IBM EBCDIC - Korean Extended |
20838 | IBM EBCDIC - Thai |
20866 | Russian - KOI8-R |
20871 | IBM EBCDIC - Icelandic |
20880 | IBM EBCDIC - Cyrillic (Russian) |
20905 | IBM EBCDIC - Turkish |
20924 | IBM EBCDIC - Latin-1/Open System (1047 + Euro symbol) |
20932 | JIS X 0208-1990 & 0121-1990 |
20936 | Simplified Chinese (GB2312) |
21025 | IBM EBCDIC - Cyrillic (Serbian, Bulgarian) |
21027 | Extended Alpha Lowercase |
21866 | Ukrainian (KOI8-U) |
28591 | ISO 8859-1 Latin I |
28592 | ISO 8859-2 Central Europe |
28593 | ISO 8859-3 Latin 3 |
28594 | ISO 8859-4 Baltic |
28595 | ISO 8859-5 Cyrillic |
28596 | ISO 8859-6 Arabic |
28597 | ISO 8859-7 Greek |
28598 | ISO 8859-8 Hebrew |
28599 | ISO 8859-9 Latin 5 |
28605 | ISO 8859-15 Latin 9 |
29001 | Europa 3 |
38598 | ISO 8859-8 Hebrew |
50220 | ISO 2022 Japanese with no halfwidth Katakana |
50221 | ISO 2022 Japanese with halfwidth Katakana |
50222 | ISO 2022 Japanese JIS X 0201-1989 |
50225 | ISO 2022 Korean |
50227 | ISO 2022 Simplified Chinese |
50229 | ISO 2022 Traditional Chinese |
50930 | Japanese (Katakana) Extended |
50931 | US/Canada and Japanese |
50933 | Korean Extended and Korean |
50935 | Simplified Chinese Extended and Simplified Chinese |
50936 | Simplified Chinese |
50937 | US/Canada and Traditional Chinese |
50939 | Japanese (Latin) Extended and Japanese |
51932 | EUC - Japanese |
51936 | EUC - Simplified Chinese |
51949 | EUC - Korean |
51950 | EUC - Traditional Chinese |
52936 | HZ-GB2312 Simplified Chinese |
54936 | Windows XP: GB18030 Simplified Chinese (4 Byte) |
57002 | ISCII Devanagari |
57003 | ISCII Bengali |
57004 | ISCII Tamil |
57005 | ISCII Telugu |
57006 | ISCII Assamese |
57007 | ISCII Oriya |
57008 | ISCII Kannada |
57009 | ISCII Malayalam |
57010 | ISCII Gujarati |
57011 | ISCII Punjabi |
65000 | Unicode UTF-7 |
65001 | Unicode UTF-8 |
Identifier | Name |
1 | ASCII |
2 | NEXTSTEP |
3 | JapaneseEUC |
4 | UTF8 |
5 | ISOLatin1 |
6 | Symbol |
7 | NonLossyASCII |
8 | ShiftJIS |
9 | ISOLatin2 |
10 | Unicode |
11 | WindowsCP1251 |
12 | WindowsCP1252 |
13 | WindowsCP1253 |
14 | WindowsCP1254 |
15 | WindowsCP1250 |
21 | ISO2022JP |
30 | MacOSRoman |
10 | UTF16String |
0x90000100 | UTF16BigEndian |
0x94000100 | UTF16LittleEndian |
0x8c000100 | UTF32String |
0x98000100 | UTF32BigEndian |
0x9c000100 | UTF32LittleEndian |
65536 | Proprietary |
- Product: The product the license is for.
- Product Key: The key the license was generated from.
- License Source: Where the license was found (e.g., RuntimeLicense, License File).
- License Type: The type of license installed (e.g., Royalty Free, Single Server).
- Last Valid Build: The last valid build number for which the license will work.
This setting only works on these components: AS3Receiver, AS3Sender, Atom, Client(3DS), FTP, FTPServer, IMAP, OFTPClient, SSHClient, SCP, Server(3DS), Sexec, SFTP, SFTPServer, SSHServer, TCPClient, TCPServer.
FIPS mode can be enabled by setting the UseFIPSCompliantAPI configuration setting to true. This is a static setting that applies to all instances of all components of the toolkit within the process. It is recommended to enable or disable this setting once before the component has been used to establish a connection. Enabling FIPS while an instance of the component is active and connected may result in unexpected behavior.
For more details, please see the FIPS 140-2 Compliance article.
Note: This setting is applicable only on Windows.
Note: Enabling FIPS compliance requires a special license; please contact sales@nsoftware.com for details.
Setting this configuration setting to true tells the component to use the internal implementation instead of using the system security libraries.
This setting is set to false by default on all platforms.
Trappable Errors (Poly1305 Component)
Poly1305 Errors
104 | Cannot read or write file. |
108 | Invalid key size. |
304 | Cannot write file. |
305 | Cannot read file. |